17.3 1 Vpp measuring systems with programmable SSI interface

17.3.1 Activating the menu for additional functions

A special menu needs to be activated to use the additional functions. For this purpose the encoder input must
be set to "PROG. SSI" by means of the parameter P9.
To activate the menu for the additional functions, now (P9 = MSYS input: PROG.SSI) press the three soft
keys on the left simultaneously.
Then the following options are available:
Press the ESC soft key to exit the menu of the additional functions.
The menu can only be activated, if the encoder input is set to
"PROG. SSI".
The additional parameters are only displayed, if the encoder
input is set to "PROG. SSI".
The encoder supply voltage Up can be applied to PIN2 (IN).
An Up pulse can be applied to PIN5 (IN) for more than 1 ms.
An Up pulse can be applied to PIN6 (IN) for more than 1 ms.
Up can be changed from 5V to HTL (10 – 30V).
- 73 -