Notes On The Installation Of Welding Current Leads - EWM alpha Q Progress drive 4D EF Operating Instructions Manual

Wire feed unit
Table of Contents

Advertisement

5.4

Notes on the installation of welding current leads

Incorrectly installed welding current leads can cause faults in the arc (flickering).
Lay the workpiece lead and hose package of power sources without HF igniter (MIG/MAG) for as
long and as close as possible in parallel.
Lay the workpiece lead and hose package of power sources with HF igniter (TIG) for as long as
possible in parallel with a distance of 20 cm to avoid HF sparkover.
Always keep a distance of at least 20 cm to leads of other power sources to avoid interferences
Always keep leads as short as possible! For optimum welding results max. 30 m (welding lead +
intermediate hose package + torch lead).
099-005459-EW501
17.12.2015
Design and function
Notes on the installation of welding current leads
Figure 5-2
27