5.8.12 Conventional MIG/MAG Welding (GMAW non synergic)

With wire-feed speeds less than 8 m/min select JOB 188.
With wire-feed speeds over 8 m/min select JOB 187.
You can only change the JOB number when no welding current is flowing.
Operating
element

5.8.12.1 Setting the operating point (welding output)

The operating point (welding performance) is set using the wire-feed speed and the welding voltage.
Operating
element
The settings are made using the rotary dials for welding parameter setting and arc length correction.
Operating
element
Operating
element
099-005459-EW501
17.12.2015
Action
Result
Select JOB list.
1 x
(LED
Set JOB number.
Wait 3 s until the setting has been applied.
Action
Result
Switch the display between:
n x
Welding current (display of actual and hold value only)
Material thickness
Wire speed
After welding, the values used last
from the main program are displayed.
Action
Result
Increase or reduce the welding performance via the wire speed
parameter.
JOB 188: from 1-8 m/min
JOB 187: from 8-21 m/min
Action
Result
Set the welding voltage.
Setting range: -9.9 V-9.9 V
is on)