Design and function
Interfaces for automation

5.12.1 Remote control connection socket, 19-pole

Pin
Signal form
A
Output
C
Output
D
Input
E
Output
F/S
Input
G
Input
P
Input
R
Input
U/V
Output
88
Figure 5-54
Short description
Connection for PE cable screen
Reference voltage for potentiometer 10 V (max. 10 mA)
Control voltage specification (0 V–10 V) – wire feed speed
Reference potential (0 V)
Welding power start/stop (S1)
Control voltage specification (0 V–10 V) – arc length correction
Activation of control voltage specification for wire feed speed (S2)
For activation, put signal to reference potential 0 V (pin E)
Activation of control voltage specification for arc length correction (S3)
For activation, put signal to reference potential 0 V (pin E)
Supply voltage push/pull welding torch
099-005459-EW501