Download Print this page

Wiring Connections - Viking AES-2005 Technical Practice

Accessible entry system with color video camera
Hide thumbs Also See for AES-2005:

Advertisement

Step 1. To mount the unit to a wall, unlock the panel using the key provided and swing the front panel open.
Step 2. Use the single gang or junction box holes provided in the back of the enclosure for alignment.
Step 3. Fasten the enclosure securely to the wall using the (4) outer chassis mounting holes.
If the enclosure is to be mounted outdoors, use an appropriate sealant between the enclosure and the wall.
Front View of Steel Surface Mount Chassis
Chassis Mounting Holes
Junction Box Holes
0.875" Diameter
Knockout
C. Wiring Connections
Two POTs are provided to increase or decrease
speaker volume and microphone sensitivity. In
certain noisy locations the speaker volume can
be increased and the microphone sensitivity
may need to be decreased as shown.
Setting the microphone gain too high may cause
distorted audio and prevent the distant party
from breaking over.
Once the AES-2005 is secured to the wall, the unit can be connected to the building wiring as described below.
Step 1. Cut off the 2.1 mm plug from the end of the AC power adapter cord. The AC adapter can be located up to 100 feet away from the
entry system when using a minimum of 24 AWG wire.
Step 2. Make all connections to the AES-2005 panel before inserting the adapter into a wall outlet. The two wires from the AC adapter connect
to the two terminal block positions labeled "13.8 VAC".
Step 3. If the incoming telephone line has an RJ-11 connector, connect it to the RJ-11 jack on the control board. Two terminal positions marked
positions marked "C.O." are also provided for a striped wire connection.
Step 4. The AES-2005 can be wired to operate a single door strike, or a door strike and an automatic door opener. The doorstrike and door
strike power supply should be wired to the terminal positions labeled "Door Strike 1". Both normally open and normally closed contacts
are available.
Step 5. If your automatic door requires a contact closure for activation, wire it to the terminal positions labeled "Door Strike 2". Both normally
open and normally closed contacts are available.
Step 6. If the installation requires a postal lock, a normally open momentary key switch can be wired to the terminal block positions labeled
"Postal Lock".
Step 7. If a C-3000 is to be used, connect a pair of wires from the AES-2005 terminal block labeled "C-3000" to the C-3000 entry phone
connection. The phone numbers for the lines wired to the C-3000 must have a "C" programmed as the first character (see
Programming). For more information, retrieve Fax Back Document 162 and 868.
Step 8. After all the connections are made, close and lock the hinged panel.
Step 9. The last step is to connect the A.C. power adapter to a wall outlet. When power is connected to the system, the front display should
show "Welcome!"
4
(3) Hinge Holes
Single Gang Box Holes
C.O. Line
or Analog
PABX/KSU
station
Video Camera
Connections
Relay Contact Specs:
(see Installation
5A @ 30VDC/250V AC
Note: Gate controllers do not
typically require power.
Doorstrike/Magnetic Lock #1
Normally Open Relay Contact
- or -
Normally Closed Relay Contact
location of the
* Optional Braille
"Audio" label may be adhered above the push button.
"Audio" label (included)
AUDIO
AES-2000
Hinge
Rear View of the AES-2005
SPK VOL
MIC VOL
M icrophone
S peaker
V olume
Yellow
Red
Black
section D)
To C-3000
To help steer visually impaired visitors to the
button, the optional Braille
Steel Surface Mount
Chassis (included)
(3) Screws (included) for
mounting the AES-2000 to the
surface mount chassis.
AES-NET Wiegand/CAN Network Board
included, see Fax Back Document 196.
1
8
J9
V olume
J1
J2
1
2
1
4
120V AC
Keyed Momentary or
Postal Lock with
Momentary Switch
Normally Closed Relay Contact
- or -
Normally Open Relay Contact
Doorstrike/Magnetic Lock #2
Use Sealant
13.8V AC
Adapter
included
Relay Contact Specs:
5A @ 30VDC/250V AC
Note: Gate controllers do not
typically require power.