C. Wiring Connections
Two POTs are provided to
increase or decrease speak-
er volume and microphone
sensitivity.
In certain noisy
locations the speaker volume
can be increased and the
microphone sensitivity may
need to be decreased as
shown. Caution: Setting the
microphone gain too high
may cause distorted audio
and prevent the distant party
from breaking over.
Relay Contact Specs:
5A @ 30VDC/250V AC
Note: Gate controllers do not
typically require power.
Once the AES-2005 is secured to the wall, the unit can be connected to the building wiring as described below.
Step 1. Cut off the 2.1 mm plug from the end of the AC power adapter cord. The AC adapter can be located up to 100 feet away from the entry
system when using a minimum of 24 AWG wire.
Step 2. Make all connections to the AES-2005 panel before inserting the adapter into a wall outlet. The two wires from the AC adapter connect
to the two terminal block positions labeled "13.8 VAC".
Step 3. If the incoming telephone line has an RJ-11 connector, connect it to the RJ-11 jack on the control board. Two terminal positions
marked "C.O." are also provided for a striped wire connection.
Step 4. The AES-2005 can be wired to operate a single door strike, or a door strike and an automatic door opener. The doorstrike and door
strike power supply should be wired to the terminal positions labeled "Door Strike 1". Both normally open and normally closed contacts
are available.
Step 5. If your automatic door requires a contact closure for activation, wire it to the terminal positions labeled "Door Strike 2". Both normally
open and normally closed contacts are available.
Step 6. If the installation requires a postal lock, a normally open momentary key switch can be wired to the terminal block positions labeled
"Postal Lock".
Step 7. If a C-3000 is to be used, connect a pair of wires from the AES-2005 terminal block labeled "C-3000" to the C-3000 entry phone
connection. The phone numbers for the lines wired to the C-3000 must have a "C" programmed as the first character (see
Programming). For more information, see DOD# 162 and 868.
Step 8. After all the connections are made, close and lock the hinged panel.
Step 9. The last step is to connect the A.C. power adapter to a wall outlet. When power is connected to the system, the front display should
show "Welcome!"
Note: The door strike and door opener can be tested using the default keyless entry code programmed in the panel. Dial "#" plus "00864" on the
AES-2005 keypad.
D. Wiring the AES-2005 Video Camera
1. Using RG59 for Video and CAT5 for Camera Power (Recommended)
Back View of the AES-2005
1
J9
J9
J1 J1
1
Audio Detect DIP Switches
ON
OFF
C.O. Line
To C-3000
or Analog
PABX/KSU
station
Doorstrike/Magnetic Lock #1
Normally Open Relay Contact
- or -
Normally Closed Relay Contact
3-Wire Gel-Filled Butt Connectors
included (3M Scotchlok UR2)
Center conductor
stripped back 5/8"
Yellow (Video)
8
Black
**** Female "F" to Wire or "BNC" to Wire
J2 J2
2
1
4
- Black (GND)
** Camera GND (-)
** Camera Pwr (+)
+ Red (6VDC)
ON
1
2
J4
J4
J12
J12
1
1
ON
S1
1
2
1
Speaker
Volume
R12
R12 R39
R39
-
8
1
1
Normally Closed Relay Contact
Normally Open Relay Contact
Doorstrike/Magnetic Lock #2
*** RG59 or RG6 Shielded
Video Cable up to 1000 ft
Twisted foil and braided shield
**** For ease of installation, a Viking Female
OR
Yellow/Red
"F" to Wire Converter Cable can be used (Part
# 261217) or "BNC" to wire converter cable
(Part # U213510) can be used. Go to
www.vikingelectronics.com and click on
"Spare Parts" to order.
Converter Cable (not included)
CAT5 Cable
W/O
Orange
** Up to 250 ft
1
1
J2
J2
J2
J2
10
10
Microphone
Volume
+
1
6
13.8V AC
120V AC
Keyed Momentary or
Postal Lock with
Momentary Switch
Note: Gate controllers do not
- or -
"F"
"F" to Phono Plug
Connector
Adapter
(Radio
Shack part #278-252)
5V DC Adapter
Camera GND (-)
W/O
Orange
Camera Power (+)
Crimp-on Splice
Connectors (not included)
Rear View
of the
AES-2005
AES-NET
Wiegand/CAN
Network Interface
included
Adapter
included
Relay Contact Specs:
5A @ 30VDC/250V AC
typically require power.
To unused input on TV,
VHF modulator, whole
house video distribution
equipment, IP video
encoder (Axis M7001), etc.
!
(included)
Black
120V AC
(-)
( + )
Black with
White Stripe
5