TH-103VX200W
2. Remove 2 Hexagonal-Head screws and 5 screws ( ) and
1 screws ( ) and 4 screws ( ) and then remove HX-
Board Block.
3. Turn over the HX-Board Block.
4. Disconnect the connectors (HX1).
5. Remove 2 Hexagonal-Head screws and 1 screws ( ) and
1 screws ( ) and then remove HX-Board Block.
9.5.
Removal of DS-Board
1. Remove HX-Board Block.
(Refer to Removal of HX-Board)
2. Remove 3 screws and then remove the DS-Board and
Fixed Plate.
3. Disconnect the connector (DS44).
4. Remove the flexible cables from the connectors (DS1).
5. Remove 2 screws and then remove DS-Board.
9.6.
Removal of A-Board
Check that no bright points appears by Ve Life adjustment
after both A and D board exchange.
1. Remove HX-Board Block.
(Refer to Removal of HX-Board)
2. Remove the DS-Board Fixed Plate.
(Refer to Removal of DS-Board)
3. Disconnect the connector (A3, A6, A7, A8, A9, A22, A33,
A44).
4. Remove the flexible cables from the connectors (A1, A10,
A16).
26