Jamr Technology BC31L User Manual

Jamr Technology BC31L User Manual

Fully automatic upper arm blood pressure monitor

Advertisement

Quick Links

Fully Automatic Upper Arm
Blood Pressure Monitor
Model Number: BC31L/BC31LT
USER'S MANUAL
Shenzhen Jamr Technology Co., Ltd.
A101-301, D101-201, Jamr Science & Technology Park, No. 2
Guiyuan Road, Guixiang Community, Guanlan Street, Longhua
District, Shenzhen 518100, PEOPLE'S REPUBLIC OF CHINA
Shanghai International Holding Corp. GmbH (Europe)
Eiffestrasse 80, 20537 Hamburg, Germany.
shholding@hotmail.com
Version Number:1.0

Advertisement

Table of Contents
loading

Summary of Contents for Jamr Technology BC31L

  • Page 1 Fully Automatic Upper Arm Blood Pressure Monitor Model Number: BC31L/BC31LT USER’S MANUAL Shenzhen Jamr Technology Co., Ltd. A101-301, D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community, Guanlan Street, Longhua District, Shenzhen 518100, PEOPLE'S REPUBLIC OF CHINA Shanghai International Holding Corp.
  • Page 2: Table Of Contents

    CONTENTS 1.Introduction and Intended Use............2.Important Information on Blood Pressure and its Measurement..3. Components of Your Blood Pressure Monitor........4. Using Your Monitor for the First Time..........5.Measurement Procedure..............6.Care and Maintenance............... 7. Warranty/service................8. Certifications..................9. Technical Specifications..............10.
  • Page 3: Introduction And Intended Use

    1.2 Warnings and Precautions 1.Introduction and Intended Use The use of other accessories other than those specified or Warning: This device is a fully automatic digital blood pressure measuring device,it electromagnetic radiation to increase or decrease is intended to measure systolic and diastolic blood pressure as well as the electromagnetic immunity resulting in operational failure pulse by wrapping around the upper arm with cuff circumference ranging from 22cm to 42cm .
  • Page 4: Important Information On Blood Pressure And Its Measurement

    To avoid damaging the device, keep this unit away from children Caution: 2.Important Information on Blood Pressure and pets. and its Measurement The standard material used for the bladder and tubing is latex-free. Caution: The device is intended for monitoring,and not for a diagnsis. Attention: 2.1.
  • Page 5: Components Of Your Blood Pressure Monitor

    There are six grids in the display of device. Please refer to the picture-01-01. Different grids represent different interval scales of WHO. 3. Components of your blood pressure monitor Picture-03 3.2 The symbols on the LED display 1.USER 1 2.USER 2 3.Bluetooth symbol 4.Cuff wrap correct symbol 5.Cuff wrap error symbol...
  • Page 6: Using Your Monitor For The First Time

    B.Setting the User ID(1 or 2): 4. Using your Monitor for the First Time With the unit off,Press the Users button and then you can set the User ID user by pressing the Users button. 4.1 Battery Power checking C.Setting the User ID/Year/Month/Date/ hour system/Time/Volume: The battery is built-in chargeable Lithium battery.
  • Page 7: Measurement Procedure

    5.3. Measure Procedure 5. Measurement Procedure The device is designed to take measurements and store the measurement values in memory for two people using User ID 1 and User ID 2. 5.1. Before measurement: Refer to picture-06 1. Sit comfortably in a chair with your feet flat on the floor. measurement.
  • Page 8 g) Movement error symbol ( 5.5. Error Indicates The Movement Error Symbol ( ) is displayed if you move your body The following symbol will appear on the display when measuring abnormal during the measurement. Please remove the cuff, and wait 2-3 minutes. Reapply the cuff and take another measurement.
  • Page 9 Trouble removal Medical device Put up Problem Check Cause and solutions Fragile Check the battery power Replace new one No power Installation for proper placement Check the polarity position Afraid of the rain of the batteries polarities Fear of the sun Whether the plug insert Insert into the air socket tightly No inflation...
  • Page 10: Care And Maintenance

    Note: 6.Care and Maintenance If you decide to delete the all memory, please keep the memory in another way, incase you need it some days later. Take the battery out won’ t lead to Wash hands after each time measurement. a memory missing.
  • Page 11: Warranty/Service

    1) *This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and Model: BC31L/BC31LT this unit can be affected by portable and mobile RF communications Weight: 259g (battery is not included) Display: 132×55mm(5.2"×2.17") LED Digital Display...
  • Page 12 Guidance and manufacture’s declaration – electromagnetic immunity Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment.
  • Page 13 Guidance and manufacture’s declaration – electromagnetic emission Guidance and manufacturer’s declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer of the The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 14 FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This manual is also suitable for:

Bc31lt

Table of Contents