Jamr Technology B06T User Manual

Upper arm type blood pressure monitor

Advertisement

Quick Links

CONTACT INFORMATION
Upper Arm Type Blood Pressure Monitor is legal manufactured by:
Company name: Shenzhen Jamr Technology Co., Ltd
Address: A101-301,D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road,
Guixiang Community,Guanlan Street, Longhua District, Shenzhen 518100,PEOPLE'S
REPUBLIC OF CHINA
Website: www.jiemeirui.com
Telephone: 0086 755 85292057
Authorized European Representative:
Company Name: Shanghai International Holding Corp. GmbH (Europe)
Contact person: Mr JIN LIANG
Address:
Eiffestrasse 80, 20537 Hamburg, Germany.
Telephone:
+49-40-2513175 / 2513178
FAX:
+49-40-255726
E-mail:
shholding@hotmail.com
Release date: 2021.03.15, Version:A0
1

Advertisement

Table of Contents
loading

Summary of Contents for Jamr Technology B06T

  • Page 1 CONTACT INFORMATION Upper Arm Type Blood Pressure Monitor is legal manufactured by: Company name: Shenzhen Jamr Technology Co., Ltd Address: A101-301,D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, Shenzhen 518100,PEOPLE'S REPUBLIC OF CHINA Website: www.jiemeirui.com...
  • Page 2 Upper Arm Type Blood Pressure Monitor Model Number: B06T -------------------------------------------------------------------------- USER MANUAL CONTENTS...
  • Page 3: Table Of Contents

    1. Introduction and Intended Use....................3 2. Important Information on Blood Pressure and its Measurement...........5 3. Components of your blood pressure monitor................. 7 4. Using your Monitor for the First Time..................8 5. Measurement Procedure..................... 9 6. Care and Maintenance......................18 7.
  • Page 4: Introduction And Intended Use

    1.Introduction and Intended Use The device is intended to measure systolic and diastolic blood pressure as well as the pulse by wrapping around the upper arm with cuff circumference ranging from 22cm to 40cm . The device is used for adult that age is more than 12 years old ,and the intended populations are the patients with hypertension or need blood pressure monitoring.The device is not used for patients under dialysis therapy or on anticoagulant, antiplatelets, or steroids.
  • Page 5 • Don’t place the cuff over wound part. • Pressurization of the CUFF can temporarily cause loss of function of simultaneously used monitoring ME EQUIPMENT on the same limb. • Apply CUFF and its pressurization to any limb where intravascular access or arteriovenous (A-V) shunts exist, can temporarily interfere with blood flow and may cause injury to the patient •...
  • Page 6: Important Information On Blood Pressure And Its Measurement

    2.Do not to position the device to make it difficult to operate the disconnection device while using adaptor. 3.Do not be prone to water leakage, high temperature, moisture, direct sunlight and more or more corrosive gas environment. And Do not use this product in the above environment. Caution: To avoid any possibility of accidental strangulation, keep this unit away from children and do not drape tubing around your neck.
  • Page 7 Picture-01 Blood pressure is very high if your diastolic pressure is above 90 mmHg and/or your systolic blood pressure is over 160 mmHg, while at rest. In this case, please consult your physician immediately. Long-term values at this level endanger your health due to continual damage to the blood vessels in your body.
  • Page 8: Components Of Your Blood Pressure Monitor

    4) There are measures which you can take to reduce and even prevent high blood pressure. 3. Components of your blood pressure monitor 3.1. Measuring unit Picture-02 Picture-03 3.2 Features of Model B06T 1. Talking function 2. Data storage: 99 sets memory 3. Average value function 4. Low battery display...
  • Page 9: Measurement Procedure

    6. Auto power-off 7.Volume adjustment 4. Functions Introduction 4.1. Volume setting Short-Press “MEM/VOL+" or “MEM/VOL-" button for volume setting. The volume is a total of 3 levels with broadcast sound of “minimum volume”(level 1) - “volume down / volume up"(level 2, middle volume) - “maximum volume”(level 3), the default is level 2 (middle volume).
  • Page 10 factors influence the measurement result. Find time to relax by sitting in an armchair in a quiet atmosphere for about ten minutes before taking a measurement. • Remove any garment that fits closely to your upper arm. • Always measure on the same arm (normally left). •...
  • Page 11 Picture-04 Change the cuff may result in unacceptable risks,the operator should pay attention to the following: • Only use Jamr authorized cuffs, as those not approved for use with the device may provide inaccurate measurements, injury, and/or damage the device. •...
  • Page 12 Health care BLE NMT Co Picture-05 Data transmit APP STEP2- Press the Power on/off button to open the Bluetooth of B06T unit STEP3- Open the Bluetooth of receiving end (smart phone,IPad) STEP4- Register the user’s information (name,age,gender,height&weight and so on). See the Picture-06 user registering interface.
  • Page 13 Picture-07 Device selecting interface Picture-08 Device connect interface STEP6-User Setting 6.1 Press the “ ”, user can see the Picture-09 ,and then user edit information or add new Users. 6.2 Voice Language Setting:User can choose the appropriate voice language, see the Picture-10.
  • Page 14 Picture-11 connecting Picture-12 Connecting Picture-13 Connecting Interface successfully unsuccessfully STEP8-Taking measurement Once the pressure monitor is connect with receiving end with Bluetooth, user can start measurement on the Health Care BLE . Press the “START”button and start the testing as shownPicture-14.
  • Page 15 Picture-15 Measurement Picture-16 Measurement data data display display as chart Recommended Use Methods 1. recommendation that the PATIENT relax as much as possible and not talk during the measurement PROCEDURE 2. recommendation that 5 min should elapse before the first reading is taken 3.
  • Page 16 Picture-17 5.6. Error Indicates SYMBOL CAUSE CORRECTION No air pressuring Battery lack of power Charge the battery After press the “start/stop”button Sensor abnormal Check if the pump is working or not. If it is working, then the problem is sensor abnormal.
  • Page 17 5.7 Trouble shooting 5.8 SYMBOL DESCRIPTIONS The following symbols may appear in this manual, on the Digital Blood Pressure Monitor B06T, or on it's accessories. Some of the symbols represent standards and compliances associated with the Digital Blood Pressure Monitor B06T and its use.
  • Page 18 fragile Keep dry Avoid the sun handle gently temperature range 5.9. Discontinuing a Measurement If it is necessary to interrupt a blood pressure measurement for any reason (e.g the patient feels unwell), the Start/Stop button can be pressed at any time. The device then immediately lowers the cuff pressure automatically.
  • Page 19: Care And Maintenance

    6. Care and Maintenance Wash hands after each time measurement. If one device is used by different patients, wash hands before and after each use. The device,including cuff should be cleaned every week,and the effective repetitive cleaning times is 390 times during the shelf life. a) Do not expose the device to either extreme temperatures, humidity, dust or direct sunlight.
  • Page 20: Technical Specifications

    9. Technical Specifications Model: B06T Wight: 237g (AC adapter is not included) Display: None Size: 120 (W) x 62 (L) x 29(H) mm Accessories: 1×Main Device, 1×Cuff, 1×Users manual, 1×Warranty card Operating Conditions: Temperature: 5℃ to 40℃;Humidity: 15% to 93% RH;...
  • Page 21 10.2 EMC Declaration * This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment. * Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit.
  • Page 22 relative humidity should be at least 30%. Electrical fast ±2 kV for power supply Not applicable Mains power quality should be transient/burst lines that of a typical commercial or hospital environment. IEC 61000-4-4 ±1 kV for input/output lines Surge ± 1 kV line(s) to line(s) Not applicable Mains power quality should be that of a typical commercial or...
  • Page 23 Recommended separation distance d=0.35√p 150 kHz to 80 MHz d=1.2√p 3 V RMS outside the Conducted RF Not applicable ISM band, 6 V RMS IEC 61000-4-6 in the ISM and amateur bands 80% AM at 1kHz 80MHz to 800MHz: Radiated RF 10 V/m 10 V/m d=1.2√p...
  • Page 24 customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment. Separation distance according to frequency of transmitter Rated maximum output 150 KHz to 80 MHz...
  • Page 25 Guidance and manufacturer’s declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device, should assure that it is used in such an environment.
  • Page 26: Warranty Card

    The MANUFACTURER should consider reducing the minimum separation distance, based on RISK MANAGEMENT, and using higher IMMUNITY TEST LEVELS that are appropriate for the reduced minimum separation distance. Minimum separation distances for higher IMMUNITY TEST LEVELS shall be calculated using the following equation: Where P is the maximum power in W, d is the minimum separation distance in m, and E is the IMMUNITY TEST LEVEL in V/m.