Fully Automatic Upper Arm
Blood Pressure Monitor
Model Number: B02T
USER'S MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Jamr Technology B02T

  • Page 1 Fully Automatic Upper Arm Blood Pressure Monitor Model Number: B02T USER’S MANUAL CONTACT INFORMATION: Digital Blood Pressure Monitor B02T is legal manufactured by: Company name: Shenzhen Jamr Technology Co., Ltd. Address: 2nd Floor, A-building, No.2 Guiyuan Road, Guihua community, Guanlan town, Longhua new district, 518100 Shenzhen, PEOPLE’S REPUBLIC OF CHINA...
  • Page 2 Now you too can enjoy the benefits of B02T engineering and quality in the home. This feature rich instrument was designed to simplify the measurement of blood pressure and pulse rate at home and deliver consistent, dependable results.Your B02T digital blood pressure monitor...
  • Page 3: Table Of Contents

    CONTENTS 1.Introduction and Intended Use This manual is for B02T models. It is a fully automatic digital blood pressure measuring device for use by adults on the upper arm at home or in your doctor’s/nurse’s office. It enables very fast and reliable 1.Introduction and Intended Use............
  • Page 4 Warning: No modification of this equipment is allowed. NOTE! Warning: The device is not suitable for use in the presence of flammable ‡ 7KLV GHYLFH FRQWDLQV VHQVLWLYH HOHFWURQLF FRPSRQHQWV $YRLG VWURQJ HOHFWULFDO anesthetic mixtures with air or with oxygen or nitrous oxide. or electromagnetic fields in the direct vicinity of the device (e.g.
  • Page 5: Important Information On Blood Pressure And Its Measurement

    There are six grids in the display of device. Please refer to the picture-01-01. 2.Important Information on Blood Pressure Different grids represent different interval scales of WHO. and its Measurement 2.1. How does high or low blood pressure arise? Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of situations through feedback from the nervous system.
  • Page 6: Components Of Your Blood Pressure Monitor

    12.Battery low symbol 13.Cuff self-checking function 14. Pulse display 15.Heartbeat symbol (Flashes during measurement) 16.WHO symbol 17.Bluetooth symbol 3.3 Features of Model B02T 1.Talking function 2. Double users: 2 x 120 sets memory Music On/Off 3.Cuff self-checking function 4. Irregular heartbeat checking 5.
  • Page 7: Using Your Monitor For The First Time

    Setting Month/Date: 4. Using your Monitor for the First Time Initial Month/Date is 1/01, when the Month display is flashing, press the MEM button, the month will increase by 1, press SET button to confirm, and do in the 4.1 Activating the pre-installed batteries same way to set the date.
  • Page 8: Measurement Procedure

    5.3. Fitting the Cuff 5. Measurement Procedure Please refer to picture-06 a) The cuff is preformed for easier use. Remove tight or bulky clothing from Note: your upper arm. You should always be seated and calm before and during measurement. b) Wrap the cuff around your upper left arm.
  • Page 9 5.4. Measure Procedure c)Connect Bluetooth Refer to picture-07 After the setting is finished, click the HOME button on the top right corner as The monitor is designed to take measurements and store the measurement picture App 01, then select Bluetooth Device button. A moment later, the values in memory for two people using User ID A and User ID B.
  • Page 10 2 ) Operate on the device e)Checking the measurement In the frame of home interface, it will show the last measurement as picture a) Press the START/STOP button. The pump begins to inflate the cuff. In the App 09. You can display, the increasing cuff pressure is continually displayed.
  • Page 11 Recommended Use Methods If pulse irregularities occur during measurement, the irregular heartbeat symbol is displayed after the measurement. If the symbol appears more 1.Recommendation that the PATIENT relax as much as possible and not talk frequently (e.g. several times per week on measurements performed daily) or during the measurement PROCEDURE if it suddenly appears more often than usual, we recommend the patient to 2.Recommendation that 5 min should elapse before the first reading is taken...
  • Page 12 The following symbols may appear in this manual, on the Digital Blood totally 240 sets(User A and B). Pressure Monitor B02T, or on it's accessories. Some of the symbols represent standards and compliances associated with the Digital Blood Pressure Monitor Viewing the stored values B02T and its use.
  • Page 13: Care And Maintenance

    The battery compartment is located on the back side of the unit. Note: No power is taken from the batteries while the AC adapter is connected a) Remove cover from the bottom plate, as illustrated below picture-08 to the monitor. If electrical power is interrupted,(e.g., by accidental removal of b) Insert the batteries (4 x size AAA ).
  • Page 14: Warranty

    This may result in incorrect operation of the unit. 3) * Caution: This unit has been thoroughly tested and inspected to assure Model: B02T proper performance and operation! Wight: 267g (Batteries and AC adapter are not included) Display: 58*85mm【3.35”x2.28”】...
  • Page 15 Guidance and manufacture’s declaration – electromagnetic immunity Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment.
  • Page 16 Guidance and manufacture’s declaration – electromagnetic emission Guidance and manufacturer’s declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer of the The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 17: Warranty Card

    FCC Statement This device complies with part 15 of the FCC rules. Operation is subject 11. Warranty Card to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.