Jamr Technology B07 User Manual

Jamr Technology B07 User Manual

Upper arm type blood pressure monitor

Advertisement

Quick Links

CONTACT INFORMATION
Upper Arm Type Blood Pressure Monitor is legal manufactured by:
Company name: Shenzhen Jamr Technology Co., Ltd
Address: A101-301,D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road,
Guixiang Community,Guanlan Street, Longhua District, Shenzhen 518100,PEOPLE'S
REPUBLIC OF CHINA
Website: www.jiemeirui.com
Telephone: 0086 755 85292057
Authorized European Representative:
Company Name: Shanghai International Holding Corp. GmbH (Europe)
Contact person: Mr JIN LIANG
Address:
Eiffestrasse 80, 20537 Hamburg, Germany.
Telephone:
+49-40-2513175 / 2513178
FAX:
+49-40-255726
E-mail:
shholding@hotmail.com
Release date: 2021.03.15, Version:A0
1

Advertisement

Table of Contents
loading

Summary of Contents for Jamr Technology B07

  • Page 1 CONTACT INFORMATION Upper Arm Type Blood Pressure Monitor is legal manufactured by: Company name: Shenzhen Jamr Technology Co., Ltd Address: A101-301,D101-201, Jamr Science & Technology Park, No. 2 Guiyuan Road, Guixiang Community,Guanlan Street, Longhua District, Shenzhen 518100,PEOPLE'S REPUBLIC OF CHINA Website: www.jiemeirui.com...
  • Page 2 Upper Arm Type Blood Pressure Monitor Model Number: B07 -------------------------------------------------------------------------- USER MANUAL...
  • Page 3: Table Of Contents

    CONTENTS 1. Introduction and Intended Use....................3 2. Important Information on Blood Pressure and its Measurement...........5 3. Components of your blood pressure monitor................. 7 4. Using your Monitor for the First Time..................8 5. Measurement Procedure..................... 9 6. Care and Maintenance......................16 7.
  • Page 4: Introduction And Intended Use

    1.Introduction and Intended Use The device is intended to measure systolic and diastolic blood pressure as well as the pulse by wrapping around the upper arm with cuff circumference ranging from 22cm to 40cm . The device is used for adult that age is more than 12 years old ,and the intended populations are the patients with hypertension or need blood pressure monitoring.The device is not used for patients under dialysis therapy or on anticoagulant, antiplatelets, or steroids.
  • Page 5 • Too frequent measurements can cause injury to the PATIENT due to blood flow interference • Don’t place the cuff over wound part • Pressurization of the CUFF can temporarily cause loss of function of simultaneously used monitoring ME EQUIPMENT on the same limb •...
  • Page 6: Important Information On Blood Pressure And Its Measurement

    operation,, otherwise it will cause injury. Warning: This equipment shall not be serviced or maintained while in use with the patient Warning: The patient is an intended operator, the functions of monitoring blood pressure and pulse rate can be safely used by patient. The routine clean and changing batteries can be performed by the patient.
  • Page 7 Picture-01 There are six grids in the display of device. Please refer to the picture-01-01. Different grids represent different interval scales of WHO. Picture-01-01 Blood pressure is very high if your diastolic pressure is above 90 mmHg and/or your systolic blood pressure is over 160 mmHg, while at rest.
  • Page 8: Components Of Your Blood Pressure Monitor

    • Correctly measured diastolic blood pressure values above 120mmHg require immediate medical treatment. 2.3. What can be done if regular high or low values are obtained? 1) Consult your doctor. 2) Increased blood pressure values (various forms of hypertension) are associated with considerable health risks over time.
  • Page 9: Using Your Monitor For The First Time

    10.Movement error symbol 11.User B 12.User A 13.WHO indicator 14.Mute symbol 15.Cuff self-checking function 3.3 Features of Model B07 1. Talking function 2. Double users: 2 x 120 sets memory 3.Cuff self-checking function 4. Irregular heartbeat checking 5. Average value function 6.
  • Page 10: Measurement Procedure

    After you load the battery or connect power for the monitor, press the power button and hold it for more than 3 seconds, and then you can start to set: Setting the User: Press the memory button to select User A or User B. When display A (/B) on the screen, press the memory button to switch to user B (/A).
  • Page 11 5.2. Common sources of error: Note: Comparable blood pressure measurements always require the same conditions! •Conditions should always be quiet. •All efforts by the user to support the arm can increase blood pressure. Make sure you are in a comfortable, relaxed position and do not flex any of the muscles in the measurement arm during the measurement.
  • Page 12 Picture-06 Change the cuff may result in unacceptable risks,the operator should pay attention to the following: • Only use Jamr authorized cuffs, as those not approved for use with the device may provide inaccurate measurements, injury, and/or damage the device. •...
  • Page 13 indicator is only a caution. It is important that you be relaxed, remain still and do not talk during measurements. NOTE: We recommend contacting your physician if you see this indicator frequently. f) The measurement results are displayed until you switch the device off if no button is pressed for 60 seconds, the device switches off automatically.
  • Page 14 Picture-07 5.5. Irregular Heartbeat Detector This symbol - indicates that certain pulse irregularities were detected during the measurement. In this case, the result may deviate from your normal basal blood pressure – repeat the measurement. In most cases, this is no cause for concern. However, if the symbol appears on a regular basis (e.g.
  • Page 15 Measurement result is Occasionally-measure for one more abnormal (SYS≦45mmHg, time/ Always - send it to local DIA≦24mmHg) distributor Too loose cuff or air leakage Tie the cuff correctly and make sure (Cannot inflate to 30mmHg the air plug is properly inserted in the within 15s) unit Er 5...
  • Page 16 SYMBOL DESCRIPTIONS The following symbols may appear in this manual, on the Digital Blood Pressure Monitor B07, or on it's accessories. Some of the symbols represent standards and compliances associated with the Digital Blood Pressure Monitor B07 and its use.
  • Page 17 fragile Keep dry Avoid the sun handle gently temperature range 5.7. Memory At the end of a measurement, this monitor automatically stores each result with date and time. Each unit stores 120 sets measurements for 2 users, totally 240 sets(User A and B). Viewing the stored values With the unit off, press the Memory button.
  • Page 18 Picture-08 Which batteries and which procedure? Use four new, longlife 1.5V AAA batteries. Do not use batteries beyond their expiration date. If the monitor is not going to be used for a prolonged period the batteries should be removed. Using rechargeable batteries You can also operate this instrument using rechargeable batteries.
  • Page 19: Care And Maintenance

    monitor. c) Plug the adapter into your electrical outlet. When the AC adapter is connected, no battery current is consumed. Note: No power is taken from the batteries while the AC adapter is connected to the monitor. If electrical power is interrupted, (e.g., by accidental removal of the AC adapter from the outlet) the monitor must be reset by removing the plug from the socket and reinserting the AC adapter connection.
  • Page 20: Certifications

    Electromagnetic compatibility: Device fulfills the stipulations of the International standard IEC60601-1-2 9. Technical Specifications Model: B07 Wight: 225.5g(batteries and AC adapter is not included) Display: 65mm x48mm LCD Digital Display Size: 144(W) x 120 (L) x 67(H) mm Accessories: 1×Main Device, 1×Cuff, 1×Users manual, 1×Warranty card Operating Conditions: Temperature: 5℃...
  • Page 21 portable and mobile RF communications equipment. * Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. * Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation! * Caution: this machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify...
  • Page 22 Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Electromagnetic environment - Immunity test IEC 60601 test level Compliance level guidance...
  • Page 23 is intended for use in the electromagnetic environment specified below. The customer or the user device of the should assure that it is used in such an environment. device Immunity IEC 60601 test Compliance Electromagnetic environment - guidance test level level Portable and mobile RF communications equipment should be used no closer to any part of the device,...
  • Page 24 additional measures may be necessary, such as re‐orienting or relocating the device. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Recommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 25: Warranty Card

    The MANUFACTURER should consider reducing the minimum separation distance, based on RISK MANAGEMENT, and using higher IMMUNITY TEST LEVELS that are appropriate for the reduced minimum separation distance. Minimum separation distances for higher IMMUNITY TEST LEVELS shall be calculated using the following equation: Where P is the maximum power in W, d is the minimum separation distance in m, and E is the IMMUNITY TEST LEVEL in V/m.