MedeaWiz® Sprite® 4K
.

Address Mode

Select an address, if desired, for serial communications to multiple Sprites from one control.
Only applies if the setting Control Mode is set to Serial Control.
Address is set to Do not use Address
If you are using a single Sprite® on the serial communications line, or using a Hydra® input
expander, in most cases you should choose the Do not use Address option.
Address is set to 0xE1 through EF
If the Sprite® 4K is set to an Address, then the Sprite® 4K will only follow commands preceded
by the correct address byte.
The Host can transmit commands to many Sprites on the same serial line.
This requires a 2 byte transmission: Address, Command. i.e. 0xE1, 0x03 will play the file named
003 on any player with an address that is set to 0xE1.
You should only use 1 Sprite® for the feedback to the Host to avoid data collisions.
You should only connect the RX inputs and Grounds of multiple Sprites together. See page 28
for wiring example.
All players set to any address will also respond to the Broadcast Address 0xE0.