Advertisement

Quick Links

User
Guide
KSO
©2023

Advertisement

Table of Contents
loading

Summary of Contents for Brunner KSO

  • Page 1 User Guide ©2023...
  • Page 2: Table Of Contents

    Firewood and heating power........15 Description of parts.............18 Adjusting of combustion air........18 Lighting the fire in a cold fireplace......21 Stoking up in a warm fireplace........22 Cleaning................ 23 Disposal................ 27 Troubleshooting............28 Note................30 User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 3 Subject to technical changes! Please keep the User Guide for future reference! For an extended product waranty and a good processing of spare parts de- liveries, we recommend carrying out the BRUNNER product registration on (www.produktregistrierung.brunner.de). © 2023 Brunner GmbH...
  • Page 4: Note To The Ceramic Glass Pane

    NOTE TO THE CERAMIC GLASS PANE BRUNNER uses only high quality glass ceramic. In a special manufacturing process, the glass panes become cerammed and acquire their unique features. During this process, it is technically not possible to exclude all optical im- pairments (fine scratches, solid in-clusions, tiny air bubbles) .These must...
  • Page 5: Safety Precautions

    The fireplace door must stay closed even if the fire is not burn- ing. Combustion air supply Structural installations for combustion air supply must not be changed. Regular checks must be carried out to ensure that they are functioning properly. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 6 Flammable textile fabrics must have a minimum distance of 5 cm from the vertical surfaces of the fireplace. Air gratings Do not close or cover up the warm air vents of your fireplace. Risk of fire or overheating! User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 7 In the case of chimney fire move all flammable parts and ele- ments away from the chimney. Cleaning and maintenace The functionality and safe operation of the fireplace depend on regular cleaning and professional maintenance. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 8 80 cm in front of the glass door! Fire hazard! Do not leave any flammable objects in front of the fireplace door. In- side the heat radiation range no objects with flammable parts are allowed. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 9: Device Description

    High-quality cast iron and special glass ce- ramic are used for the combustion door. The KSO is available with manual combustion air adjustment and - op- tionally - the electronic combustion control EAS. If the device is operated with EAS, the instructions for EAS must also be observed.
  • Page 10: Basic Rules For Operation

    Stoves and fireplaces from Ulrich Brunner GmbH are designed for period- ic burning. It means that always a minimal amount of firewood has to be loaded and the combustion air must be adjusted according to the following instructions.
  • Page 11 2/3, depending on chimney draught. The damper flap is installed in the flue pipe connecting piece between the heating insert and the chimney and regulates the chimney draft. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 12 • Changes to the building's tightness, e.g. through the installation of new windows or doors, insulation of roof surfaces, full thermal insulation Combustion chamber linings Important note: Single cracks on fire-resistant combustion chamber lin- ings are no reason for concern. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 13 Door sealing ropes BRUNNER is using only high-quality door sealing ropes, which are exactly adapted to the requirements of our heating devices. Yet the door sealings are wear parts, and therefore are not covered by our product warranty.
  • Page 14 * The damper flap is installed in the flue pipe connecting piece between the heating insert and the chimney and regulates the chimney draft. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 15: Firewood And Heating Power

    Natural firewood (left) is the best fuel for fireplaces, but you can use also wood briquettes according to DIN 17225-3, Class A1, length >14 cm (5.51 in), diameter >8 cm (3.15 in) (right). © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 16 Adjusting the heat by reducing the volume of combustion air is wrong! If there is not enough combustion air available, the energy contained in fire- wood cannot be completely released. At the same time, the emissions are rising due to unburned particles. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 17 KSO 33 q 2,0 kg - 4,0 kg 33 cm 4,0 kg + 4,0 kg Loading too much wood into a KSO stove or using improper fuel may cause overheating and risk of fire! © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 18: Description Of Parts

    Combustion air is supplied directly into the fireplace through a separate air connection. The combustion air flap is integrated in the front assembly, and for manually operated fireplaces it can be controlled by hand using a con- trol element. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 19 Air supply setting for keeping em- bers. All air supply openings are closed. CAUTION: Risk of deflagration! The 'Glow' position cannot be chosen until flames are visible. Respect the ventilation requirements for simultaneous operation with other fireplaces. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 20 The simultaneous operation of ventilation or exhaust air systems (extractor hood) and the fireplace can negatively affect the combustion air supply to the fireplace. This must be reliably prevented by suitable technical equip- ment. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 21: Lighting The Fire In A Cold Fireplace

    In case of rapid air streaming from the room (when fireplace door is opened) it is possible that the gases “trapped” inside the combustion chamber and downstream radiators/accumulators will suddenly react with oxygen and explode (deflagration). © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 22: Stoking Up In A Warm Fireplace

    Always place the wood logs close to the rear wall so that no parts of the fuel touch the pane even if it slips off. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 23: Cleaning

    Never use abrasive or aggressive cleaners! Curing of the sealing rope can lead to glass breakage! Replace it when necessary! Damage of sealing ropes arising from inappropriate operation or cleaning are excluded from warranty. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 24 Cleaning the ceramic glass pane Work steps when Note Removal of a light if neces- Cleaning glass from dirty residues Operator deposit sary can be done easy with a piece of wet paper towel. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 25 Ease of movement can be improved with heat-resistant dry lubricant. Supply air line (if once a Check and - if necessary - clean Specialist available) year the devices for the combustion air supply. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 26 Work steps when Note Clean the flue yearly Clean the pipe, vacuum the fly Specialist pipe ash. Fit the flue pipe tightly. Check the chimney for blockages after long periods of non-use. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 27: Disposal

    Do not put the glass ceramic discs in the waste glass collection container! The glass panes can be disposed of as normal household waste. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 28: Troubleshooting

    Wood is damp or too big pieces of firewood are used. Please use the recommend- ed fuel as indicated in these in- structions. Unusual smell Deposits of dust Heat up the stove strongly. Provide for ventilation. User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 29 Insufficient combustion air sup- Put the combustion air adjuster into ‘fire starting’ or rated power position. Check the combustion air supply and smoke outlet. Call your fire- place contractor, if possible. © 2023 Brunner GmbH User Guide KSO (1.12)
  • Page 30: Note

    User Guide. It is necessary to follow any other relevant instructions, like the “Operating instructions for tiled stove water boilers”! My stove fitting company: User Guide KSO (1.12) © 2023 Brunner GmbH...
  • Page 31 D-84307 Eggenfelden Reprinting and reproduction, even in part, only with Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 the express permission of the publisher. Email: info@brunner.de Art.Nr. : 200004 © 2023 Brunner GmbH User Guide KSO (1.12)

This manual is also suitable for:

Kso 33 q

Table of Contents