3.7
Integrated Quad-Channel SCSI Target
Mode Controller
Each integrated quad-channel SCSI target mode (STE) controller card (part number
375-0038-xx) is a 9U VME PCB and has four differential SCSI ports on its faceplate.
See
FIGURE 3-22
3.7.1

Connectors

Rear of the card—
P1—VMEbus; mates with backplane connector J1
P2—VMEbus; mates with backplane connector J2
P3—VMEbus; mates with backplane connector J3
Front of the card—
The faceplate has four independent differential SCSI ports. Each port is a 68-pin
connector
Caution – You can damage this card if you connect or disconnect cables while
termination power is present; jumpers J2, J3, J4, and J5 are factory-installed for
termination power.
3-42
Sun StorEdge A7000 Service Manual • August 1999
for a general layout
shows the connectors at the rear of the card:
FIGURE 3-22
shows the connectors at the front of the card: