Summary of Contents for Mean Well SHP-30K-HV Series
Page 1
SHP-30K-HV Series Installation manual Security Industrial Automate Telecom 30KW HVDC Power Supply 3φ3-wire wide input range High efficiency Intelligent...
Page 2
Can be working at ambient temperature up to 70 ℃ with forced air cooling. Moreover, SHP-30K-HV series provides vast design flexibility by equipping various built-in functions such as output programming, active current sharing, remote ON-OFF control, auxiliary power, and communication protocols, that will not only...
Contents 1.Safety Guidelines 6.Communication Protocol PMBus Communication 2.Introduction Interface 2.1 Model Encoding CANBus Communication 2.2 Features Interface 2 3 Specification 6 3 . us Communication 2 4 Derating curve Interface 2 5 . Mechanical specification Value range and tolerance 3.Installation & Wiring 7.Protections and Trouble 3.1 Mounting Shooting...
1.Safety Guidelines 2.Introduction 2.1 Model Encoding Risk of electrical shock and energy hazard, all failure should be examined by a qualified technician. Please do not remove the case form the power supply by SHP - yourself. Please do not change any component on the unit or make any kind of Communication protocol option modification on it.
Features Specification 3φ3-wire without Neutral / 340~530VAC wide input range MODEL SHP-30K-55 SHP-30K-115 SHP-30K-230 SHP-30K-380 DC VOLTAGE (factory default) 55V 115V 230V 380V High efficiency up to 9 % CURRENT (factory default) 346A 261A 130.5A Forced air cooling RATED RANGE 0 ~ 346A 0 ~ 261A 0 ~ 139A...
Installation Notes AC Power Connection A. Before any installation or maintenance work, please disconnect your ◎ / △ 3φ3-wire 340VAC~530VAC system from the utility. Ensure that it cannot be re-connected to the utility inadvertently. SHP-30K-HV B. Keep enough insulation distance between mounting screws and internal components of power supplies.
4.Panel and LED Indicator Pin Assignment of CN53 Panel Description -V(Signal) -V(Signal) AC input terminals DC output terminals DIP-SW: Used for parallel control/PV/PC functions Function pins: Used for control and monitoring functions. Please refer to 4.2 and 4.3. LED indictor: Indicate the status of the supply and load condition.
4. Communication Address/ID Assignment Pin No. Function Description Each SHP 30K HV unit should have their unique and own device address to communicate over the Short: Termination resistors(120 ) For CANBus MODBus Ω 、 、 CANBus, PMBus or MODBus . SW51 and S 52 allow users to designate an address or ID for the...
5.Operation 5.3.2 PV (Output Voltage Programming) A.Set DIP switch 3 to ON position Inrush Current Limiting 1 2 3 Built-in AC inrush current limiting circuit. ● Since the inrush current limiting circuit mainly consists of a NTC ● thermistor and a relay, inrush current will be much higher than the B.Connect output of external DC source to PV+ and...
Iout 5.3.3 Communication Output voltage can be adjusted through communication interfaces: PMBus, CAN bus or Modbus. Please refer to chapter 6 for detailed Non-Linear information. Non-Linear Output Current Adjustment Output current can be adjusted via PC and communication interface. ● 0.047 HORIZONTAL 5.4.1 PC (Output Current Programming)
Remote Control 5. . 5 2 SHP-30K-HV has the built-in active current sharing function and can be connected in parallel, up to 12 units or more, to provide higher output power as exhibited below : The power supply can be turned ON-OFF by using the "Remote ●...
Auxiliary Output 6.Communication Protocol uilt-in 12V/1. A auxiliary output ● There are two means to control the unit, analog signals and digital ● communication. Analog is the default setting for the unit, signals including PV, PC and SVR can be used immediately once receiving the unit.
Page 15
◎Definition of Table 6-1 Command BEh SYSTEM_CONFIG Command Command Transaction # of data Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Page Description Code Name Type Bytes High byte PAGE R/W Byte Page OPERATION R/W Byte Remote ON/OFF control Low byte OPERATION_INIT PM_CTRL ON_OFF_CONFIG...
Page 16
Bit 6 EEPER: EEPROM data access error Data Byte High Data Byte Low 0 EEPROM = data access normal 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 1 EEPROM = data access error Note: Linear Data Format Data Bytes Y, N and the "real world"...
CANBus Communication Interface 4.Set Output voltage to 56V. Physical layer specification ● Address(7 bit) Operation Command Code Data This protocol follows CAN ISO-11898 with Baud rate of 250Kbps. Data Frame ● 0x40 Write 0x22 , 0x This protocol es Extended CAN 29-bit identifier frame format or Command code: 0x22(VOUT_TRIM) CAN 2.0B.
Page 18
6.2.1 Message ID definition Table 6-2 Message ID Description Command Command Transaction # of data Description Code Name Type Bytes 0xC00XX SHP to Controller Message ID ON/OFF control 0x0000 OPERATION 0xC01XX Controller to SHP Message ID ON: 01h/OFF: 00h 0xC01FF Controller broadcasts toSHP Message ID Output voltage set...
Page 19
Bit 6 OP_OFF:DC status Command Command Transaction # of data Description 0=DC output turned on Code Name Type Bytes 1=DC output turned off Manufacture date 0x0086 MFR_DATE_B0B5 Manufacture serial number 0x0087 MFR_SERIAL_B0B5 Bit 7 HI_TEMP:Internal high temperature protection Manufacture serial number 0=Internal temperature normal 0x0088 MFR_SERIAL_B6B11...
Page 20
Bit 4:7 IOUT Factor:The Factor of DC current ◎MFR_DATE_B0B5 ( 0x0086 ) is manufacture date (ASCII) 0x = Output current relevant commands not supported MFR_DATE_B0B5 is 180101, meaning 2018/01/01 0x4=0.001 Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 0x5=0.01 0x31...
Page 21
◎SYSTEM_CONFIG byte3: (0x00C2): Bit 0:3 IIN Factor:The Factor of AC input current Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 0x = AC input current relevant commands not supported Low byte OPERATION_INIT CAN_CTRL 0x4=0.001 Bit 0 CAN_CTRL:CANBus communication control status 0x5=0.01 =...
Page 22
6.2.3.3 ractical Operation 5.It is recommended to review all of the settings and parameters using the appropriate commands. In the event that they do not meet your The following steps will describe how to set the SHP-30K-55 to 56V. requirements, you may rewrite them as needed. EX: Read VOUT_SET to 1.Set the address of the supply to 0 "...
6 3 . us Communication Interface 6.3.3 Additional Address Definition Additional address is the slave ID of the device. Each SHP- 0K- The device supports M us RTU with the master-salve principle. unit should have their unique and own device address to Users are able to read and write parameters of the device through communicate over the bus.
Page 24
Table Register Command Function # of data Description address Name code Bytes Register Command Function # of data Description address Name code Bytes Manufacture model name 0x0086 MFR_MODEL_ 0x03 Remote ON/OFF control 0x0000 OPERATION 0x03、0x06 B0B5 ON: 0x0001 Manufacture model name 0x0089 MFR_MODEL_ 0x03...
Page 25
◎FAULT_STATUS (0x0040): ◎MFR_ID_B0B5 (0x0080 - 0x0082) is the first 6 codes of the Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 manufacturer's name (ASCII); MFR_ID_B6B11(0x0083 - 0x0085) is the Low byte HI_TEMP OP_OFF AC_FAIL SHORT FAN FAIL last 6 codes of the manufacturer's name (ASCII) EX: manufacturer's name is MEANWELL →...
Page 27
◎SYSTEM_STATUS byte1: (0x00C3): Bit 0:3 VIN Factor:The Factor of AC input voltage Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 0x0=AC input relevant commands not supported INITIA- Low byte EEPER ADL_ON PFC OK DC_OK M S / LSTATE 0x4=0.001 0x5=0.01 Bit 0: M/S:parallel mode status 0x6=0.1 0=Current device is Slave...
Page 28
Request: OPERATION_INIT:Pre-set value of power on operation command 0b00=Power OFF, pre-set 0x00(OFF) 0x 0 0x04 0x 2 0x157C 0 8B81 0b01=Power ON, pre-set0x01(ON) 0x 0: Slave ID 0 0b10=Pre-set is previous set value 0x0 : Function code 4 (Read Analog Input Register) 0b11=not used, reserved 0x02: The number of data bytes to follow (2 bytes) 0x157C: The contents of register:...
Page 29
◎Adding a 120 Ω termination resistor to both the controller and 5.It is recommended to review all of the settings and parameters using the supply s end can increase communication stability. appropriate commands. In the event that they do not meet your ◎If the unit is a terminal, it is recommended to connect a termination requirements, you may rewrite them as needed.
Value range and tolerance Note: READ_IOUT will display ZERO amp when output current is less than values (1)Display parameters in the table below. Model Display value range Tolerance Model Minimum readable READ_VIN 340~530V ±10V 3 5 ±3.5A 115V 2 6 ±2.6A 230V 1 4 ±1.4A READ_IIN...
If you are unable to clarify the problem you are facing, please contact MEAN WELL or any of our distributors for repair service. to prevent damaging itself. The supply will restore automatically when AC voltage is back to a normal range.
※ MEAN WELL possesses the right to adjust the content of this manual. Please refer to the latest version of manual on our website. https://www.meanwell.com...
Page 33
N o . 2 8 , W u q u a n 3 r d R d . , W u g u D i s t . , N e w Ta i p e i C i t y 2 4 8 , Ta i w a n...
Need help?
Do you have a question about the SHP-30K-HV Series and is the answer not in the manual?
Questions and answers