Wiring And Connection; Example Of Wiring And External Connection - Nagano Keiki ZT11 User Manual

Pressure sensor for semiconductor industry
Table of Contents

Advertisement

7. WIRING AND CONNECTION

■ 7.1 Example of Wiring and External Connection
Wiring and external connections should be made as follows. Insert the M12-connector cable into the
connector slot of this Instrument. Tighten the nut by hand until it does not move (tightening torque: 0.4
to 0.5 N·m).
Connector Terminal
Use this product within the ambient temperature range of - 20 to
70 deg. C.
The product with an absolute pressure range needs to be
installed in an environment with an atmospheric pressure of 70
kPa abs. or more (altitude: approx. 3,000 m or less). The
specified performance may not be obtained when the product is
used in an environment with extremely low atmospheric
pressure.
This accurately-adjusted product may become inoperable when
being dropped or given shocks.
Select an installation location with little vibration/dust, not
exposed to direct sunlight, and without external shock.
Allow room for maintenance and adjustment around the product.
Avoid snoop test for the sensor as it may cause insulation
resistance failure.
It is recommended to fully purge the product with inert gas
before starting operation to remove atmospheric components,
particles and foreign matters within the pipe.
Terminal No.
Arrangement
2-wire System
Power (+)
Power (-)
< Table 7-1 >
12
Cabling Color
Brown
White
Blue
Black
TY-ZT11-004A Ver. 3