INSTALLATION

TECHNICAL SPECIFICATIONS: YWM-200
INPUT-SINGLE PHASE ONLY
Standard Voltage /Frequency
220V±10% 50/60Hz
110V±10% 50/60Hz
RATED OUTPUT-DC ONLY
Voltage
Duty Cycle
Mode
GMAW
100%
220V
SMAW
100%
GTAW
100%
GMAW
100%
110V
SMAW
100%
GTAW
100%
OUTPUT RANGE
Open Circuit
Voltage
Mode
Voltage
GMAW
220V
SMAW
GTAW
GMAW
110V
SMAW
GTAW
OTHER PARAMETERS
Machine Power Factor Efficiency
YWM-200
0.8
≥80%
PACKING DIMENSIONS
Machine
Length
Width
540mm
360mm
YWM-200
TEMPERATURE RANGE 
Operating Temperature Range
-20°C ~ +50°C(-4°F~122°F)
Input Current
I
=34A, I
=26.3A
1 max
1 eff
I
=50A, I
=38.7A
1 max
1 eff
Volts at Rated
Current
Current
60%
200A
24V
158A
21.9V
60%
180A
27.2V
139A
25.5V
60%
200A
18V
155A
16.2V
60%
160A
22V
123A
20.1V
60%
145A
25.8V
112A
24.5V
60%
160A
16.4V
124A
15V
Welding
Welding
Current Range
Voltage Range
30A~200A
15.5V~24V
20.8V~27.2V
20A~180A
10A~200A
10.4V~18V
62V
30A~160A
15.5V~22V
20A~145A
20.8V~25.8V
10A~160A
10.4V~16.4V
Protection Class Insulation Class
IP21S
Height
Weight
445mm
17.65Kg
Storage Temperature Range
-20°C ~ +50°C(-4°F~122°F)
Read the entire installation section before you start
the installation.
ELECTRIC SHOCK can kill.
Only qualified personnel should per-
Ÿ
form this installation.
Only personnel reading and under-
Ÿ
standing the YWM-200 Operator's Man-
ual should install and operate this
equipment.
The machine must be plugged into a grounded receptacle
Ÿ
per national, local, or other applicable electrical codes.
The YWM-200 power switch should be in the OFF("O") po-
Ÿ
sition when installing the work cable and gun and con-
necting the power cord to input power.
SELECT SUITABLE LOCATION
Locate the YWM-200 in a dry place with free clean air circula-
tion to minimize the chance of dirt accumulation that can block
air passages and cause overheating.
STACKING
F
YWM-200 cannot be stacked.
TILTING
The machine should be placed on a secure, level surface or a
recommended cart. The equipment may topple over if this re-
quirement is not followed.
- 5 -
INSTALLATION
WARNIG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents