INSTALLATION – ELECTRIC UTILITY CONNECTIONS – STANDARDS AND CODES
WARNING
!
Qualified installation personnel, licensed and bonded, must be experienced in such work, familiar with all precautions required and
have complied with all requirements of state or local authorities having jurisdiction.
U.S. AND CANADIAN INSTALLATIONS – All ovens, when installed, must be electrically grounded in accordance
with local codes, or in the absence of codes, with the National Electrical Code ANSI/NFPA 70 – Latest Edition
and/or Canadian National Electrical Code C22.2 as applicable.
The ventilation of these ovens should be in accordance with local codes. In absence of local codes, refer to the national ventilation
code titled, Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial
Cooking Equipment, NFPA-96 – Latest Edition.
GENERAL EXPORT INSTALLATIONS – Installation must conform to Local and National Standards. Local installation codes
and/or requirements may vary. If you have any questions regarding the proper installation or operation of your American Range
Convection Oven, please contact your local distributor. If you do not have a local distributor, contact American Range
Corporation at 1.888.753.9898 or visit us at www.americanrange.com
ELECTRICAL CONNECTION – The standard gas operated convection ovens require a 120 VAC, 60 Hz, 20 AMP electrical service
for operation. The supply cord provided on the appliance is equipped with a three-prong (grounding) plug for protection against
electrical shock hazard. The electrical service in the building must be equipped with a properly grounded three-prong receptacle, in
accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or in
Canada – to Canadian electrical codes, CSA C22.2. Do not cut or remove the grounding prong from this plug.
WARNING
!
For gas fired 120 VAC units and any NEC compliant receptacle, proper ground and correct
polarity is required.
Electric convection ovens are configured at the factory for operation from 208 VAC, single
phase, or 208 VAC, three-phase electrical service is also an available configuration.
WARNING
!
6
A70701 RevE 01082024
INSTALLATION
The installation instructions contained here are for the use of qualified installation and
service personnel only. Installation or service by other than qualified personnel will void the
warranty and may result in damage to the oven and/or injury to the operator.

ELECTRICAL GROUNDING INSTRUCTIONS

The appliance is equipped with a three-prong (grounding) plug for your protection against
electrical shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the grounding prong from this plug.
No attempt should be made to operate this appliance during an electrical
service failure or in the event of a prolonged power failure. The appliance is
not capable of operation without specified gas and electric requirements.
CAUTION
N
L
L
N
G
G
GOOD
NO GOOD
120 VAC POLARITY SPECS
A39074