Piper ARCHER III Pilot Operating Handbook page 81

Hide thumbs Also See for ARCHER III:
Table of Contents

Advertisement

PA-28-181,
ARCHER
III
SECTION
3
EMERGENCY
PROCEDURES
3.5
EMERGENCY
PROCEDURES
CHECK LIST
(continued)
3.5d
ElectricalFailures(continued)
+
To
ensure
30-minutes of
battery life:
Battery
Discharge.
-13 Amps
Maximum
Pitot
Heat.....
......14 Minutes
Usage
Maximum
Com Radio
Fuel
Pump
3
Mins
Usage
Maximum
2
Mins
Usage
Maximum
Innd
as soon
as
possible.
Turning
the
ALTR
switch OFF, reseting the
ALTR FIELD
circuit
breaker and then
turning
the
ALTR
back
ON,
will
reset
the
overvoltage
relay.
If
the trouble was
caused
by a
momentary overvoltage condition
(30.5 volts or higher) this
procedure
should return
the ammeter
to
a
normal
reading.
If
alternator
does not reset, the
battery
will
become the
primary
source
of
electrical
power.
The
only
electrical
bus that remains powered
in
this
load
shed
configuration is
the
ESSENTIAL BUS.
All
elecrrical items
on
the
remaining
buses
will
be inoperative
(See
Figure 7-11), including
the
AVIONICS
dimmer. Display backlighting,
therefore,
is
produced
by
the
photocell
in
each
display.
As
battery
power
is
depleted, there
may be
a
point
where the system voltage reduces
to
a
level
that
is
insufficient
to
support
the
required electrical
load.
In
this
occurrence,
the
emergency
battery should
activate
automatically.
If
the
emergency
battery
does not
activate automatically,
the BATT MASTR
and
ALTR
switches
should
be turned OFF, thereby
allowing
the
emergency
battery
to
be the only
remaining
source
of
electrical power. Refer
to
Complete Electrical
Failure
checklist
if
EMER
BATT
ON
advisory illuminates.
REPORT:
VB-2749
3-L9
ISSUED:
December 22, 2Ol7