Modbus Registers - Kohler Modbus MPAC 1000 Operation

Communications protocol for automatic transfer switches
Table of Contents

Advertisement

2.4 Modbus Registers

Register
Data Description
40001
System Overview
40002
SourceA Line--Neutral L1--L0
40003
SourceA Line--Neutral L2--L0
40004
SourceA Line--Neutral L3--L0
40005
SourceB Line--Neutral L1--L0
40006
SourceB Line--Neutral L2--L0
40007
SourceB Line--Neutral L3--L0
40008
SourceA Line Voltage L1--L2
40009
SourceA Line Voltage L2--L3
40010
SourceA Line Voltage L3--L1
40011
SourceB Line Voltage L1--L2
40012
SourceB Line Voltage L2--L3
40013
SourceB Line Voltage L3--L1
40014
SourceA Frequency
40015
SourceB Frequency
40016
Reserved for future use
40017
Reserved for future use
40018
Reserved for future use
40019
Reserved for future use
40020
Reserved for future use
40021
Reserved for future use
40022
Source Phase Sequence Actual
40023
Source Phase Sequence Expected
40024
SourceA Nominal Voltage
40025
SourceB Nominal Voltage
40026
SourceA Nominal Frequency
40027
SourceB Nominal Frequency
40028
SourceA Number of Phases
40029
SourceB Number of Phases
40030
Rated Amperage
40032
SourceA Engine Start Time Delay (ID 0x0001)
40033
SourceB Engine Start Time Delay (ID 0x0002)
40034
SourceA Ext Engine Start Time Delay (ID
0x0003)
40035
SourceB Ext Engine Start Time Delay (ID
0x0004)
40036
SourceA Engine Cooldown Time Delay (ID
0x0005)
40037
SourceB Engine Cooldown Time Delay (ID
0x0006)
40038
Preferred to Standby Time Delay (ID 0x0007)
40039
Standby to Preferred Time Delay (ID 0x0008)
40040
Off to Preferred Time Delay (ID 0x0009)
40041
Off to Standby Time Delay (ID 0x000A)
40042
Acquire Standby Source (ID 0x000B)
TP-6208 4/03
Data Type
Access
RO
Word[0:14]
0--1: Contactor Position (00 = Off; 01 = Normal; 10
= Emerg; 11 = Fault)
2: Preferred Source (0 = Source1; 1= Source2)
3--12: Top Event on Warning Stack
13: Preferred Source Available (0 = No, 1 = Yes)
14: Standby Source Available (0 = No, 1 = Yes)
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Volts AC * 10
RO
Word
Hz * 10
RO
Word
Hz * 10
Return 0
Return 0
Return 0
Return 0
Return 0
Return 0
RO
Word[0:3]
0--1: SourceA 01 = ABC; 00 = CBA; 10 = N/A; 11
= ERR
2--3: SourceB 01 = ABC; 00 = CBA; 10 = N/A; 11
= ERR
RW
Word[0]
0: 1 = ABC; 0 = CBA
RW
Word
Volts AC * 10
RW
Word
Volts AC * 10
RW
Word
Hz * 10
RW
Word
Hz * 10
RW
Word
1 or 3
RW
Word
1 or 3
RW
Word
0--4000
RW
Word
0--6 sec
RW
Word
0--6 sec
RW
Word
0--5999 sec
RW
Word
0--5999 sec
RW
Word
0--5999 sec
RW
Word
0--5999 sec
RW
Word
0--5999 sec
RW
Word
0--5999 sec
RW
Word
0--5999.9 sec * 10
RW
Word
0--5999.9 sec * 10
RW
Word
1--5999 sec
Range/Units
Section 2 Modbus Registers
7

Advertisement