Download Print this page

Danfoss 088U0200 Manual page 18

Cf-mc master controller
Hide thumbs Also See for 088U0200:

Advertisement

Available languages

Available languages

Instruction CF-MC Master Controller
6.3 Input for Global Standby and Heating & Cooling
Activate Input mode on Master Controller ( g. 23)
• Use the menu selection button
LED
ashes
• Activate Input mode by pressing OK
Select the Input con guration
• Press the output selection button
sible Input con gurations
below:
• 1 LED: The input ports are not used
• 2 LEDs: The Master Controller will switch to cooling mode when the
input for heating/cooling is activated ( g. 2 -
• 3 LEDs: The Master Controller will switch to a xed set room tem-
perature at 8 °C for all Room Thermostats when the input for global
standby is activated ( g. 2 -
• 4 LEDs: The Master Controller will switch to cooling mode when the
input for heating/cooling is activated ( g. 2 -
Master Controller will switch to a xed set room temperature at 8 °C
for all Room Thermostats when the input for global standby is acti-
vated ( g. 2 -
• Activate selected input con guration by pressing OK
18
VI.UH.K1.52
- the output LEDs will be ON – indicated
)
) (default)
Produced by Danfoss Floor Heating Hydronics 08.2005
to select the Input mode. Input
. Input LED
and toggle between the pos-
)
). In heating mode the
goes ON

Advertisement