30
(0.84)
25
(0.70)
20
(0.56)
15
(0.42)
10
(0.28)
5
(0.14)
0
0
To find Pump Air Consumption (scfm or m
specific fluid flow (gpm/lpm) and air pressure
(psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve.
3. Follow left to scale to read air consumption.
24
308797
Performance Charts
Air Consumption
Test Conditions: Pump tested in water with inlet submerged.
Air Consumption Curves
A
at 100 psi (0.7 MPa, 7 bar) air pressure
at 70 psi (0.48 MPa, 4.8 bar) air pressure
B
at 40 psi (0.28 MPa, 2.8 bar) air pressure
C
2
4
(7.6)
(15.2)
FLUID FLOW — gpm (lpm)
3
/min) at a
6
8
10
(22.7)
(30.3)
(37.9)
A
B
C
12
14
16
(53.0)
(45.4)
(60.6)