Changing the Orientation of the Fluid Inlet
and Outlet Ports
Fig. 4. You can change the orientation of the fluid inlet and
outlet ports by repositioning the manifolds.
Relieve the pressure. See
Pressure Relief Procedure on
1.
page 10.
2. Remove four manifold bolts (105).
3. Turn manifold to desired position, reinstall bolts, and
torque to 80 to 90 in-lb (9 to 10 N•m). See Torque
Sequence, page 20.
NOTE: Make sure all manifold o-rings are positioned
correctly before you fasten the manifold. Manifold o-rings
(139) are shown in Fig. 6.
Installation
Torque to 80 to 90 in-lb (9 to 10 N•m). See Torque
1
Sequence, page 20.
105
1
105
1
Fig. 4
outlet
inlet
9071A
308797