Toshiba MMK-UP0051DHPL-E(TR) Service Manual page 39

Table of Contents

Advertisement

Indoor unit function Code No. (DN Code) table
(includes functions needed to perform applied control on site)
DN
Item
Filter display delay timer
01
D
r i
y t
s
a t
e t
f o
t l i f
r e
02
Central control address
03
Specific indoor unit
04
priority
Heating temp. shift
06
Demand control
(CN73 / CN4)
0b
E
x
s i
e t
n
c
e
f o
A [
U
T
0d
m
o
d
e
C
o
o
n i l
g
o
n
y l
0F
Type
10
Indoor unit capacity
11
Line address
12
Indoor unit address
13
Group address
14
Temp difference of
A [
U
T
O
]
m
o
d
e
s
e
e l
1E
COOL
HEAT,
HEAT
COOL
Automatic restart of
28
power failure
Selection of option/Trouble 0000: Filter input
2A
input
(TCB-PCUC2E: CN3)
HA terminal (CN61)
s
e
e l
t c
2E
31
Ventilating fan control
32
TA sensor selection
0000: None
0002: 2500H
0004: 10000H
0
0
0
: 0
S
a t
n
d
a
d r
0001: High degree of dirt (Half of standard time)
0001: No.1 unit
0001: No.1 unit
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
0000: No priority
0000: 0 °C
0002: +2 °C
0000: Demand input
0002: Card input setup.3
0004: Card input setup.4
0005: Fire alarm input
(Normal close)
0007: Card input setup.5
0009: Card input setup.2
O
]
0
0
0
: 0
P
o r
v
d i
e
d
0
0
0
: 1
N
t o
p
o r
v
d i
e
(Automatic selection from connected outdoor unit)
0
0
0
: 0
H
e
t a
p
u
m
p
0001: Cooling only (No display of [AUTO] [HEAT])
Refer to Type DN code "10" list
0000: Unfixed
Refer to Indoor Unit Capacity DN code "11" list
0001: No.1 unit
0001: No.1 unit
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
0001: No.1 unit
0001: No.1 unit
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
0000: Individual
0002: Follower unit of group
00Un: Unfixed (When using U series remote controller)
0099: Unfixed (Other than U series remote controller)
0000: 0 °C
t c
o i
n
Ts:Remote controller setup temp.
0000: None
0002: None
0000: Usual
0002: Fire alarm input
(arbiter contact)
0004: Notice cord (201)
0000: Unavailable
0000: Body TA sensor
Description
0001: 150H
0003: 5000H
to
0064: No.64 unit
... TCC-LINK
to
0128: No.128 unit ... TU2C-LINK
0001: Priority
0001: +1 °C
to
0010: +10 °C
(Up to +6 recommended)
0001: O2 sensor input
0003: Fire alarm input
(Normal open)
0006: Notice cord (202)
0008: Card input setup.1
d
0001 to 0034
to
0064: No.30 unit
... TCC-LINK
to
0128: No.128 unit ... TU2C-LINK
to
0064: No.64 unit
... TCC-LINK
to
0128: No.128 unit ... TU2C-LINK
0001: Header unit of group
to
0010: 10 °C (Ts ± 5°C)
0001: Restart
0001: Alarm input
(Air washer, etc.)
0001: Card input setup.1 (3)
0003: Card input setup.2 (4)
0005: Card input setup.5
0001: Available
0001:
Remote controller sensor
- 39 -
At shipment
Depending on model
type
0
0
0
: 0
S
a t
n
d
a
d r
00Un/0099: Unfixed *1
0000: No priority
Depending on model
type
0000: Demand input
0
0
0
: 1
N
t o
p
o r
v
d i
e
d
0
0
0
: 0
H
e
t a
p
u
m
p
Depending on model
type
According to capacity
type
00Un/0099: Unfixed *1
00Un/0099: Unfixed *1
00Un/0099: Unfixed *1
0003: 3 °C
T (
s
±
1
5 .
°
C
)
0000: None
0002: None
0000: Usual
(HA terminal)
0000: Unavailable
0000: Body TA sensor

Advertisement

Table of Contents
loading

Table of Contents