Vents TwinFresh Style Wi-Fi User Manual page 8

Single-room reversible energy recovery ventilator
Hide thumbs Also See for TwinFresh Style Wi-Fi:
Table of Contents

Advertisement

Ventilation:
the ventilator runs either in air extraction or air supply mode at a set speed.
In this mode some of the ventilators in the network run in air supply mode and the other ones in air extraction mode, depending on
the position of the DIP switch No. 3 (see section
Boost: the ventilator goes to the maximum speed without changing the operation mode.
Regeneration:
the ventilator runs in two cycles, 70 seconds each, with heat and humidity regeneration.
Cycle
I. Warm stale air is extracted from the room and flows through the ceramic regenerator, which gradually absorbs heat and
humidity. In 70 seconds, as the ceramic regenerator gets warmed, the ventilator is switched to supply mode.
Cycle
II. Fresh intake air from outside flows through the ceramic regenerator, absorbs accumulated moisture and is heated up to the
room temperature. In 70 seconds, as the ceramic regenerator gets cooled down, the ventilator is switched to air extraction mode and
the cycle is renewed. If two ventilators are installed, they operate with opposite rotation directions in this mode. While one ventilator
supplies air, the other one extracts it.
Air supply:
the ventilator operates in supply mode irrespective of the position of the DIP switch No. 3 (see section
ventilator operation mode using DIP
The ventilators are equipped with a humidity sensor and terminals for connecting an external 0-10 V analogue sensor and an external
normally open contact (relay sensor). When any of these devices is triggered, the ventilator switches to maximum speed (Boost
mode).
When the sensors return to their original position, the Boost mode switch-off delay timer starts.
Relevant sections of the Vents Home mobile app allow you to configure the following ventilator settings:
switch on or off the humidity sensor, 0-10 V analogue sensor, and relay sensor;
set the triggering threshold for the humidity sensor and the 0-10 V analogue sensor;
set the Boost mode switch-off delay duration (30 minutes by default);
set the operation duration under the first speed timer ("Night" mode) (8 hours by default);
set the operation duration under the third speed timer ("Party" mode) (4 hours by default).
If necessary, you can set different ventilator speeds for different time intervals by day of the week in the "Weekly Schedule" section
of the Vents Home mobile app. For the week schedule to work correctly, you need to set the current date and time correctly in the
"Date and Time" section.
In case of simultaneous use of several modes of operation of the ventilator, which exclude each other, the ventilator selects the mode
according to the following priority:
1. The Night mode timer or the Party mode timer.
2. Standby.
3. Boost.
4. Weekly Schedule
5. Standard operation mode.
8
VENTILATOR OPERATION MODES
"Setting the ventilator operation mode using DIP
switches").
TwinFresh Style Wi-Fi (mini) (Frost) (M)
switches").
"Setting the
www.ventilation-system.com