Electrical Requirements; Exhaust System Requirements - Electrolux SAGQ7000FS0 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for SAGQ7000FS0:
Table of Contents

Advertisement

Available languages

Available languages

PRE-INSTALLATION
REQUIREMENTS
Tools and Materials
Required
for Installation:
1. Phillips head screwdriver.
2. Channel-lock
adjustable pliers.
3. Carpenter's
level.
4. Flat or straight
blade screwdriver.
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.2 cm) duct.
7. Vent hood.
8. Pipe thread
sealer (Gas).
9. Plastic knife.
ELECTRICAL REQUIREMENTS
[
ELECTR/C
Dryer
]
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay
fuses or circuit breaker.
Use separately fused circuits for washers and dryers, and DO NOT operate
a washer and a dryer on the same circuit.
POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD KIT - The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp.,
with 3 open end spade lug connectors with upturned
ends or closed loop
connectors and marked for use with clothes dryers.
WARNING
- Risk of Shock.
Appliance
grounded
to neutral conductor
through
a link.
Grounding through
the neutral link is prohibited
for (I)
New branch circuit installations (2) mobile homes; (3) recreational vehicles;
and (4) areas where local codes do not permit
grounding
through
the
neutral, (1) disconnect the link from the neutral, (2) use grounding
terminal
or lead to ground appliance in accordance with local codes and (3) connect
neutral terminal
or lead to branch circuit neutral in usual manner (if the
appliance is to be connected by means of a cord kit, use 4-conductor
cord
for this purpose).
USE COPPER CONDUCTOR ONLY. The dryer MUST
employ a 4-conductor
power supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30 amp., with 4 open end spade
lug connectors with upturned
ends or closed loop connectors and marked
for use with clothes dryers. See ELECTRICAL CONNECTIONS FOR A 4-WIRE
SYSTEM.
(Canada - 4-wire power supply cord is installed on dryer.)
OUTLET RECEPTACLE - NEMA 10-30R receptacle to be located so the
power supply cord is accessible when the dryer is in the installed position.
(Canada - NEMA 14-30R receptacle.)
NEMA 10-30R
NEMA 14-30R
i
GAS Dryer
i
CIRCUIT- Individual 15 amp. branch circuit fused with a 15 amp. maximum
time delay fuse or circuit breaker.
POWER SUPPLY- 3 wire, 120 volt single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - The dryer is equipped with
a 120 volt 3-wire
power cord.
NOTE: Do not under any
circumstances
remove
grounding
prong
from
plug,
_GXROUNDING PRONG
EXHAUST SYSTEM REQUIREMENTS
Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and
approved vent hood which has a swing-out damper(s) that open when the
dryer is in operation. When the dryer stops, the dampers automatically
close
to prevent drafts and the entrance of insects and rodents. To avoid restricting
the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between
the vent hood and the ground or any other obstruction.
The following
are specific
requirements
for proper
and safe operation
of your
dryer. Failure
to follow
these instructions
can create excessive drying
times and fire hazards.
Do not use plastic
flexible
duct to exhaust
the dryer.
Excessive lint can build up inside exhaust system and create a fire hazard and
restrict air flow. Restricted air flow will increase dryer times. If your present
system is made up of plastic duct or metal foil duct, replace it with a rigid or
flexible metal duct
Ensure the present
duct is free of any lint prior
to
installing
dryer duct.
rf_m
- Risk of Fire - A clothes dryer produces combustible
lint. If
the dryer is not exhausted outdoors
some fine lint will be expelled into the
laundry area. An accumulation
of lint in any area of the home can create a
health and fire hazard. The dryer
must
be connected
to an exhaust
outdoors.
Regularly
inspect the outdoor
exhaust opening
and remove
any accumulation
of lint around the outdoor
exhaust opening and in the
surrounding
area.
Do not allow
combustible
materials
(for
example:
clothing,
draperies/curtains,
paper)
to come in contact
with
exhaust
system. The dryer MUSTNOT
be exhausted into a chimney, a wall, a ceiling,
or any concealed space of a building which can accumulate lint, resulting in
a fire hazard.
Exceeding the length
of duct pipe or number of elbows
allowed
in the "MAXIMUM
LENGTH" charts carl cause an accumulation
of Nnt in the exhaust system. Plugging the system could create a fire hazard,
as well as increase drying times.
Do not screen the exhaust
ends of the vent system,
nor use any screws or rivets to assemble
the exhaust
system.
Lint can
become caught in the screen, on the screws or rivets, clogging the duct work
and creating a fire hazard as well as increasing drying times. Use an approved
vent hood to terminate the duct outdoors, and seal all joints with duct tape.
All male duct pipe fittings MUST be installed downstream with the flow of
air.
Explosion
hazard.
Do not
install
the dryer
where
gasoline
or other flammables
are kept or stored.
If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor.
Failure to do so can result in death, explosion, fire or burns.
MAXIMUM
LENGTH
of 4" (10.2 cm) Dia. Rigid Metal
Duct
VENT HOOD TYPE
Number
(Preferred)
of
Louvered
%
.q
(10.2 cm)
(6.35 cm)
0
60 ft.
(18.28 m)
48 ft.(14.6S m)
1
52 ft.
(15.84 m)
40 ft.(12.19 m)
2
44 ft.
(13.41 m)
32 ft. (9.75 m)
3
32 ft.
(9.75 m)
24 ft. (7.31 m)
4
28 ft.
(8.53 m)
16 ft.
(4.87 m)
MAXIMUM
LENGTH
Number
of 4" (10.2 cm) Dia. Flexible Metal
Duct
of
VENT HOOD TYPE
90 °
(Preferred)
0
30 ft.
(9.14 m)
18 ft. (5.49 m)
1
22 ft.
(6.71 m)
14 ft. (4.27 m)
2
14 ft.
(4.27 m)
10 ft. (3.05 m)
3
NOT RECOMMENDED