installation Requirements
Exhaust
system
requirements,
continued
The dryer must be connected to an exhaust
outdoors.
Regularly inspect the outdoor exhaust
opening and remove any accumulation
of lint
around the outdoor exhaust opening and in the
surrounding area.
Z
o
E*
0
1
2
3
4
Z
o
E*
0
1
2
3
MAXIMUM LENGTH
of 4" (10.2cm) Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
4"
(10.2cm)
Iouvered
125 ft. (38.10m)
115 ft. (35.05m)
105 ft. (32.00m)
95 ft. (28.96m)
85 ft. (25.91 m)
2.5"
(6.35cm)
110 ft. (33.53m)
100 ft. (30.48m)
90 ft. (27.43m)
80 ft. (24.38m)
70 ft. (21.34m)
MAXIMUM LENGTH
of 4" (10.2cm)Semi-Rigid
Metal Duct
VENT HOOD TYPE
(Preferred)
4"
(10.2cm)
Iouvered
60 ft. (18.29m)
50 ft. (15.24m)
40 ft. (12.19m)
NOT RECOMMENDED
2.5"
(6.35cm)
45 ft. (13.72m)
35 ft. (10.67m)
25 ft. (7.62m)
Install male fittings
in correct
direction:
In installations where the exhaust system is not
described in the charts, the following method
must be used to determine if the exhaust system
is acceptable:
CORRECT
INCORRECT