WARNING: The measurement results given by this device
is not a diagnosis. It is not replacing the need for the consul-
tation of a physician, especially if not matching the patient's
symptoms. Do not rely on the measurement result only,
always consider other potentially occurring symptoms and
the patient's feedback. Calling a doctor or an ambulance is
advised if needed.

3. How this Thermometer measures Temperature

This thermometer measures infrared energy radiated from the
forehead as well as objects. This energy is collected through the
lens and converted to a temperature value.

4. Control Displays and Symbols

 All segments displayed 8: Press the START/IO button 4 to
turn on the unit; all segments will be shown for 1 second.
 Ready for measuring 9: When the unit is ready for
measuring, the «°C» or «°F» icon will keep flashing while the
mode icon (body or object) will be displayed.
 Measurement complete AT: The reading will be shown on the
display 3 with the «°C» or «°F» icon and the mode icon
steady. Press the START/IO button 4 again to go back to the
«ready for measuring» mode 9, or wait 5 sec when «°C» or
«°F» icon is flashing again. The device is ready for the next
measurement.
 Low battery indicator AM: When the unit is turned on, the
icon will keep flashing to remind the user to replace the
batteries.

5. Setting Date, Time and Beeper Functions

Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display BN. You can set the year by pressing the M-button 5.
To confirm and then set the month, press the MODE button 6.
2. Press the M-button 5 to set the month. Press the MODE
button 6 to confirm and then set the day.
3. Follow the previously mentioned instructions to set the day,
hours and minutes.
4. Once you have set the minutes and pressed the START/IO
button 4, the date and time are set and the time is displayed.
If no button is pressed for 20 seconds, the device automat-
ically switches to ready for measuring 9.
3
Cancel time setup: Press the START/IO button 4 during
time setup. The LCD will show Date/Time icons with «--:--».
After that press the START/IO button 4 to start the
measurement. If no further action is taken within 30
seconds, the device will automatically turn off.
Change current date and time: Press and hold the MODE
button 6 for approx. 8 seconds until the year number
starts to flash BN. Now you can enter the new values as
described above.
Setting the beeper
1. Press and hold the MODE button 6 for 3 seconds to set the
beeper BO.
2. Press the M-button 5 to either turn the beeper on or off. The
beeper is activated when the beeper icon BO is shown without
a cross.
When the beeper setting has been chosen, press the
START/IO button 4 to enter the «ready for measuring»
mode 9; otherwise the device automatically switches to
ready for measuring after 10 seconds.

6. Changing between Body and Object Mode

1. Press the START/IO button 4. The display 3 is activated to
show all segments for 1 second.
2. The default mode is body mode AK. Press the MODE button 6
to switch to object mode AL. For switching back to body mode,
press the MODE button again.

7. Directions for Use

Measuring in body mode
1. Press the START/IO button 4. The display 3 is activated to
show all segments for 1 second.
2. When the «°C» or «°F» icon is flashing, a beep sound is heard
and the thermometer is ready for measuring 9.
3. Remove any hair, sweat or dirt from the forehead before
measuring to ensure the accuracy of the readings.
4. Aim the thermometer at the center of the forehead with a
distance of no more than 5 cm.
5. Press the START/IO button 4 and ensure that the
activated blue tracking light is aimed at the center of the
forehead. After 3 seconds a long beep will verify the comple-
tion of measurement.