Komatsu 15045 Operation & Maintenance Manual page 507

Hydraulic mining shovel
Table of Contents

Advertisement

MAINTENANCE
Motor Adapter Housing, Change Oil:
1. Remove level gauge (4) and breather filter (5). Insert the hose
of a suction pump into the gauge pipe (4) until the hose end
just touches the bottom of the T-union. Place the oil outlet
hose of the suction pump into a receptacle. Switch on the
pump and completely suck off the oil from the motor housing.
If a suction pump is not available, place a receptacle below
drain plug (6).
Remove plug (6) and drain the oil completely.
2. Clean breather filter (5) with compressed air from inside to
outside and re-install.
3. If removed, install drain plug (6) and fill-up gear oil through
filler opening (4), up to the "MAX" mark on level gauge (4)
and install the level gauge.
4. After short operating period check oil level and housing for
leaks.
4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR