Komatsu 15045 Operation & Maintenance Manual page 135

Hydraulic mining shovel
Table of Contents

Advertisement

OPERATION
Menu Control with Key Switch (C) and Key Group
(D)
Setting of Operational Data, menu item Service
*SETTINGS*
Example: Changing the pause time of the Central Lubrication
System (on machines with factory installed lube systems only).
Starting from the menu level -1-, *SERVICE* see menu control
charts I and III (Z25242).
Proceed as follows:
1. Select menu level -1- by pressing "QUI" key (10) the starting
menu item *Truck counter reading:* appears on the display,
see chart I.
Press key (12) three times, the main group *SERVICE* is dis-
played. Press key (10), level -2- with menu item *LAN-
GUAGE* appears on the display.
2. Press key (12) three times, the menu point *SETTINGS
appears on the display.
3. Press key (10), *PTO GEAR-OIL VISCOSITY* in level 3, see
chart III appears on the display.
4. Press key (12) two times, the item *CENTRAL LUBRICATION
SYSTEM* is displayed.
5. Press key (10), level 4 with the starting menu item *CONDI-
TION INDICATION* appears on the display.
6. Press key (12) once, the display changes tto menu item
*PAUSE TIME* with the information of the present
*PAUSE TIME (e.g.)
7. Press key (10) again, the display changes to level 5 with the
information "Settings OPERATE KEY SWITCH".
8. Operate key switch (C), now the "pause time: 01:00"
is displayed.
9. Use key (4) of the Text display keyboard to position the cursor
below the numerical value that shall be changed.
10. Use key (2 and/or 3) "UP/DOWN" of the Text display key-
board for changing the numerical value.
11. Acknowledge the new setting by pressing key (1). The infor-
mation on the display changes over to the introductory mes-
sage page -0- or if a message is present to the respective
message page.
01:00* appears on the display.
"new pause time: 01:00 "
3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS
135