4 . Release all buttons .
5 . Press the UNIT button to select NFe or Fe test mode .
6 . Press and hold the probe 
surface of the naked substrate 
from the substrate once the display 
display shows the reading 1 .80 mm .
7 . Press the TEST button to increase the reading on the
display .
8 . Press the UNIT button to decrease the reading on the
display .
NOTE: The reading should equal the thickness value of
the calibration plate 
the calibration plate is 1 .76 mm, press the UNIT button to
decrease the reading on the display to 1 .76 mm .
9 . Place the calibration plate onto the naked substrate .
24 GB
perpendicularly against the
1 ]
[
. Move the product away
8 ]
[
. For example, if the thickness of
7 ]
[
shows
2 ]
[
. The