Trane 5TEM6B02AV21SA Installation, Operation And Maintenance Manual page 3

Convertible air handlers
Table of Contents

Advertisement

C C A A U U T T I I O O N N
C C O O I I L L I I S S P P R R E E S S S S U U R R I I Z Z E E D D ! !
• •
C C o o i i l l i i s s p p r r e e s s s s u u r r i i z z e e d d w w i i t t h h a a p p p p r r o o x x i i m m a a t t e e l l y y 8 8 – – 1 1 2 2 p p s s i i
d d r r y y a a i i r r a a n n d d f f a a c c t t o o r r y y c c h h e e c c k k e e d d f f o o r r l l e e a a k k s s . .
• •
C C a a r r e e f f u u l l l l y y r r e e l l e e a a s s e e t t h h e e p p r r e e s s s s u u r r e e b b y y r r e e m m o o v v i i n n g g t t h h e e
r r u u b b b b e e r r p p l l u u g g o o n n t t h h e e l l i i q q u u i i d d l l i i n n e e . .
• •
I I f f n n o o p p r r e e s s s s u u r r e e i i s s r r e e l l e e a a s s e e d d , , c c h h e e c c k k f f o o r r l l e e a a k k s s . .
W W A A R R N N I I N N G G
S S A A F F E E T T Y Y H H A A Z Z A A R R D D ! !
T T h h i i s s a a p p p p l l i i a a n n c c e e i i s s n n o o t t t t o o b b e e u u s s e e d d b b y y p p e e r r s s o o n n s s
( ( i i n n c c l l u u d d i i n n g g c c h h i i l l d d r r e e n n ) ) w w i i t t h h r r e e d d u u c c e e d d p p h h y y s s i i c c a a l l , ,
s s e e n n s s o o r r y y , , o o r r m m e e n n t t a a l l c c a a p p a a b b i i l l i i t t i i e e s s , , o o r r l l a a c c k k o o f f
e e x x p p e e r r i i e e n n c c e e a a n n d d k k n n o o w w l l e e d d g g e e , , u u n n l l e e s s s s t t h h e e y y h h a a v v e e b b e e e e n n
g g i i v v e e n n s s u u p p e e r r v v i i s s i i o o n n o o r r i i n n s s t t r r u u c c t t i i o o n n c c o o n n c c e e r r n n i i n n g g t t h h e e
u u s s e e o o f f t t h h e e a a p p p p l l i i a a n n c c e e b b y y a a p p e e r r s s o o n n r r e e s s p p o o n n s s i i b b l l e e f f o o r r
t t h h e e i i r r s s a a f f e e t t y y . .
W W A A R R N N I I N N G G
W W A A R R N N I I N N G G ! !
T T h h i i s s p p r r o o d d u u c c t t c c a a n n e e x x p p o o s s e e y y o o u u t t o o c c h h e e m m i i c c a a l l s s
i i n n c c l l u u d d i i n n g g l l e e a a d d , , w w h h i i c c h h a a r r e e k k n n o o w w n n t t o o t t h h e e S S t t a a t t e e o o f f
C C a a l l i i f f o o r r n n i i a a t t o o c c a a u u s s e e c c a a n n c c e e r r a a n n d d b b i i r r t t h h d d e e f f e e c c t t s s o o r r
o o t t h h e e r r r r e e p p r r o o d d u u c c t t i i v v e e h h a a r r m m . . F F o o r r m m o o r r e e i i n n f f o o r r m m a a t t i i o o n n g g o o
t t o o w w w w w w . . P P 6 6 5 5 W W a a r r n n i i n n g g s s . . c c a a . . g g o o v v . .
I I m m p p o o r r t t a a n n t t : : Installation of this unit shall be made in
accordance with the National Electric Code,
NFPA No. 90A and 90B, and any other local
codes or utilities requirements.
I I m m p p o o r r t t a a n n t t : : Air handlers do not require repositioning of
the coil, drain pan, or refrigerant sensor for
upflow applications. Horizontal left
applications require sensor repositioning
only. Horizontal right and downflow
applications require coil, drain pan, and
sensor repositioning. See coil conversion
instructions section for details.
N N o o t t e e : : Air handlers have been evaluated in accordance
with the Code of Federal Regulations, Chapter
XX, Part 3280 or the equivalent. "SUITABLE FOR
MOBILE HOME USE."
N N o o t t e e : : Condensation may occur on the surface of the air
handler when installed in an unconditioned
space. When units are installed in unconditioned
spaces, verify that all electrical and refrigerant
line penetrations on the air handler are sealed
completely.
18-GF79D1-1A-EN
N N o o t t e e : : The manufacturer recommends installing ONLY
A.H.R.I approved, matched indoor and outdoor
systems. Some of the benefits of installing
approved matched indoor and outdoor split
systems are maximum efficiency, optimum
performance, and the best overall system
reliability.
N N o o t t e e : : There is no declared maximum altitude for
operating the appliance.
N N o o t t e e : : Charging of the refrigerating system shall be
according to the instructions provided by the
manufacturer of the outdoor unit.
Features
Table 1. Standard Features
MULTI-POSITION UPFLOW, DOWNFLOW, HORIZONTAL LEFT
AND HORIZONTAL RIGHT
PAINTED FINISH ON GALVANIZED STEEL EXTERIOR WITH
FULLY INSULATED CABINET THAT MEETS R4.2 VALUE
STURDY POLYCARBONATE DRAIN PANS
These air handlers have factory installed drain pans and
are shipped for upflow applications
208/230 VAC OPERATION
VARIABLE-SPEED DIRECT DRIVE BLOWER
FACTORY INSTALLED R-410A THERMAL EXPANSION VALVE
ALL ALUMINUM COIL
BOTTOM RETURN
MEETS THE MINIMUM LEAKAGE REQUIREMENTS FOR THE
FLORIDA AND CALIFORNIA BUILDING CODES
Table 2. Optional Accessories
4,5,8,10,15,20, and 25 KW SINGLE PHASE ELECTRIC
HEATERS
Circuit breakers available on single phase 4, 5, 8, 10,
15, 20, and 25 KW heaters
Lugs available on single phase 4, 5, 8, and 10 KW
heaters
Lugs available on three phase 10 and 15 KW heaters
SINGLE POINT POWER ENTRY KIT (for 15 and 20 KW
heaters)
SUPPLY DUCT FLANGE KIT
DOWNFLOW SUB-BASE KITS - TAYBASE185, TAYBASE235,
TAYBASE260
SLIM FIT FILTER BOX KIT - BAYSF1185AAA, BAYSF1235AAA,
BAYSF1265AAA
Breaker Seal Kit - TEMBRKSEALKT01A
Downflow Condensate Management Kit - BAYTEMDFKT1A
CleanEffects Whole House Air Cleaners - EFD175DLAH000B,
EFD215DLAH000B, EFD235DLAH000B
120V Unit Conversion Kits - BAYAH120KT
S S A A F F E E T T Y Y S S E E C C T T I I O O N N
3