Maintenance

Maintenance of Inactive Charging Stations

When the charger is not in use, the charger should be in a power-off state.
To maintain the service life of the charger, unnecessary load should be reduced,

Charger Checks and Maintenance Cycle

Item
Period
Front-end
distribution
Every 3 months
box
Every 12
Appearance
months
Every 12
Interior
months
Lightning
Every 12
protector
months
Fan
Every 6 months
Signal lamp
Every 6 months
Components
Every 6 months
Charging
Every 6 months
connector
Power
Every 6 months
module
Every 6 months
Human
EVUCMM-V01R1 Maintenance Manual
October 2023
Each item is checked in accordance with the
maintenance manual of the distribution box.
(Note: The maintenance manual of the distribution box
is provided by the supplier of distribution box.)
Check the appearance of the cabinet for any stains.
Check whether the cabinet shell has any rust,
scratches, deformation, paint damage or other
defects.
Make sure the interior of the cabinet is clean and tidy.
Make sure the air inlet and outlet of the power module
are not blocked with debris or dust.
Clean air ways allow more effective cooling and
prevent premature failure of the power module.
Check whether the module is securely connected, and
the status indicator is normal. If the status indicator
changes to red, the dry contact NC-COM of alarm
becomes open or the NC-COM becomes short-
circuited, the surge protector has failed.
Make sure the fan is working correctly.
Make sure the signal lamp is working correctly. Make
sure it is fixed tightly and in a normal state.
Check whether components of the electric circuit
have discoloration, deformation, overheating, or other
defects, and make sure all accessible components are
secure.
If any abnormality is found, parts must be replaced in
a timely manner.
Make sure the fixing clasp is not damaged.
the needle of the charging connector is oxidized and
discoloured or obviously worn and deformed, whether
any foreign body has entered the hole on the head of
the connector, and whether the charging connector
cable is damaged.
Check that the power module is normal and there is a
trouble-free display on the module screen.
Check the display screen to see if it is cracked or not
Details
Maintenance
Action
Maintenance
and repairing
Cleaning and
paint repair
Cleaning
Replacement
Maintenance
and repairing
Maintenance
and repairing
Maintenance
and repairing
Cleaning and
repairing
Maintenance
and repairing
Maintenance
UltraCharge 160 DC Charger
Page 8 of 22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sinexcel ULTRACHARGE 160 and is the answer not in the manual?

Table of Contents