ROLEC Sinexcel ULTRACHARGE 160 Maintenance Manual page 10

Intelligent ultra-rapid ev charging station
Hide thumbs Also See for Sinexcel ULTRACHARGE 160:
Table of Contents

Advertisement

Maintenance
Item
Period
machine
interface
Emergency
Every 6 months
stop function
Equipment
Every 6 months
grounding
System
Every 6 months
grounding
Every 12
Slot
months
Breaker
Monthly
Every 12
Electric cable
months
Force
majeure
Immediately
factor
UltraCharge 160 DC Charger
Page 9 of 22
functioning properly.
Press the emergency stop button to check that charge
point functionality is stopped.
Reset the emergency stop button to check that
charge point functionality is restored.
Check whether the ground wire of the equipment
housing is tightened and connected.
Check whether the grounding cable inside the cabinet
is loose or detached. And check if the grounding sign is
complete and obvious.
Check whether the slot is fixed firmly, whether the
cover plate is complete and tight.
Press the TEST button of the circuit breaker to see
whether the circuit breaker can trip properly.
Check whether the cable and switch are connected
closely, whether the grounding is reliable, whether the
power cable is normal, and whether the sealing
measures at the incoming cable of the cabinet are
intact.
In case of flood, earthquake, impact, switch trip and
other events, the whole machine should be checked
immediately.
Details
EVUCMM-V01R1 Maintenance Manual
Action
and repairing
Maintenance
and repairing
Maintenance
and repairing
Maintenance
and repairing
Maintenance
and repairing
Maintenance
and repairing
Repairing and
replacement
of cables
Maintenance
and repairing
October 2023