Commissioning - MAXIMATOR SLGP 3 Series Installation And Operating Manual

Air driven liquefied gas pump
Table of Contents

Advertisement

5.4.2

Commissioning

Risk of injury due to extreme temperatures!
The surfaces of the product can be very hot or very cold. This can lead to acci-
dents resulting in severe injuries or death.
► Before working on the product, please ensure that the product is at ambient
temperature.
Details about how to start up the pump is described in the following:
1)
Check all connections for proper installation.
2)
Check all connecting lines for mechanical damage.
3)
Slowly open the supply line.
– The compressed fluid flows in.
4)
Slowly open the compressed air line of the compressed air line system to the
pump.
– The pump automatically starts to deliver.
We recommend slowly increasing the pressure of the drive air to keep the stress
on the pump components low during commissioning.
The stroke frequency of the pump is kept low this way. Otherwise, during the
ramp-up phase, until the required operating pressure is reached, operating
phases with very high cycle frequencies can occur.
0000000383 - 001 - EN
WARNING
Installation
26