Spool valve "V" ventilation port
Ventilation and bleeding of the spool valve. The port must not be obstructed.
Pilot valve "Y" exhaust port
Bleeding of the spool valve actuator chamber. An air pulse escapes here after
each stroke. The port must not be obstructed.
This port can be used to connect a stroke counter.
Bleed port high-pressure side "Z"
Discharge of the leakage from the high-pressure unit and the pneumatic drive. A
bleed pipe can be connected. The bleed port opening must not be obstructed.
3.6
Technical specifications
3.6.1
Operating conditions
Ambiance
Specification
Ambient temperature, min.
Ambient temperature, max.
Installation area
Tab. 3-1 Ambient conditions
Operating fluids (based on ISO 8573-1)
Specification
Operating temperature, minimum
Operating temperature, maximum.
max. particle count at 0.1 - 0.5 µm size
max. particle count at 0.5 - 1.0 µm size
max. particle count at 1.0 - 5.0 µm size
max. solids, particle concentration
Particle size, max.
a. Depending on the design of the liquefied gas pump (see enclosed general drawing)
b. Depending on the design of the liquefied gas pump (see enclosed general drawing)
Tab. 3-2 Operating fluids
0000000383 - 001 - EN
Product description
Value
- 20
+ 60
protected against
climatic exposure
Value
a
- 20
b
+ 60
not indicated
(Class 3)
90,000 (Class 3)
1,000 (Class 3)
5 (Class 6)
10
Unit
°C
°C
Unit
°C
°C
pcs.
pcs.
pcs.
mg/m³
µm
18