Lenovo ThinkSystem SR670 Reference Manual page 95

Hide thumbs Also See for ThinkSystem SR670:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0039
User Action:
Information only; no action is required
• FQXSPPU2007I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
• FQXSPPW0001I: Power supply [arg1] in the enclosure (MTM-SN: [arg2])has been added.
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0084
User Action:
Information only; no action is required
• FQXSPPW0002L: Power supply [arg1] in the enclosure (MTM-SN: [arg2])has failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Please check event log in system management module (SMM) to identify the power supply unit failure
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
.