Lenovo ThinkSystem SR670 Reference Manual page 27

Hide thumbs Also See for ThinkSystem SR670:
Table of Contents

Advertisement

Table 2. Events organized by severity (continued)
Message String
Event ID
FQXSPOS4002I
Watchdog [arg1] Failed to Capture Screen.
FQXSPOS4003I
Platform Watchdog Timer expired for [arg1].
FQXSPOS4010I
OS Crash Video Capture Failed.
FQXSPPU0001N
An Over-Temperature Condition has been detected on
[ProcessorElementName].
FQXSPPU0003N
[ProcessorElementName] has Failed with IERR.
FQXSPPU0004M
[ProcessorElementName] has Failed with FRB1/BIST condition.
FQXSPPU0007N
CPU voltage mismatch detected on [ProcessorElementName].
FQXSPPU0009N
[ProcessorElementName] has a Configuration Mismatch.
FQXSPPU0011N
An SM BIOS Uncorrectable CPU complex error for
[ProcessorElementName] has asserted.
FQXSPPW0002L
Power supply [arg1] in the enclosure (MTM-SN: [arg2])has failed.
FQXSPPW0007L
[PowerSupplyElementName] has a Configuration Mismatch.
FQXSPPW0035M
Numeric sensor [NumericSensorElementName] going low (lower
critical) has asserted.
FQXSPPW0047M
Numeric sensor [NumericSensorElementName] going high (upper
critical) has asserted.
FQXSPPW0061M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
FQXSPPW0063M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
FQXSPPW0110M
Non-redundant:Insufficient Resources for
[RedundancySetElementName] has asserted.
FQXSPSD0001L
Drive [arg1] in the enclosure(MTM-SN: [arg2]) has been disabled due
to a detected fault.
FQXSPSD0002L
Drive [arg1] in the enclosure(MTM-SN: [arg2]) has been disabled due
to a detected fault.
FQXSPSD0005L
Array critical asserted on drive [arg1] in the enclosure (MTM-S/N:
[arg2]).
FQXSPSD0006L
Array failed on drive [arg1] in the enclosure (MTM-S/N: [arg2]).
FQXSPSD0007L
Array critical asserted on drive [arg1] in the enclosure (MTM-S/N:
[arg2]).
FQXSPSD0008L
Array failed on drive [arg1] in the enclosure (MTM-S/N: [arg2]).
FQXSPSE4000I
Certificate Authority [arg1] has detected a [arg2] Certificate Error.
FQXSPSR0001N
Sensor [SensorElementName] has transitioned to non-recoverable
from a less severe state.
FQXSPUN0019M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
FQXSPUN0023N
Sensor [SensorElementName] has transitioned to non-recoverable.
Severity
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
.
Chapter 2
XClarity Controller events
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

7y367y377y38