IMPORTANT CONTENTS • • Please bear in mind the weight of the The accessories are found in a box Recycling & Safety Warnings ............................. 4 fire before removing from the packaging that is packed at the side of the fire. UKCA &...
RECYCLING & SAFETY WARNINGS RECYCLING & SAFETY WARNINGS • Children of less than 3 years should be due to overheating. The element will kept away unless continuously supervised. continually and automatically cut out if the airflow is obstructed. Never cover the •...
RATINGS PRODUCT TYPE MANUFACTURED BY TRADE NAME RATINGS PRODUCT TYPE MANUFACTURED BY Flamerite Fires LTD. Greenhough Road, Flamerite Fires LTD. Greenhough Road, EF-X 220-240 Vac, 50Hz Class 1 Electric Fire (fan heater) Lichfield. Staffs. WS13 7AU. EF-X 110 Vac, 60Hz Class 1 Electric Fire (fan heater) Lichfield.
It is preferable to fit the fire to a 13A 110 VOLT fused spur for safety. This ensures it has it’s own supply and will not overload current installations. BLANKING E-FX FIRE LOG SET PLATES...
BLANKING PLATE INSTALLATION SIDE PANEL INSTALLATION If you have purchased a 1 or 2 sided E-FX Fire, you will need to install the blanking plates BEFORE fitting the fire or installing into a chimney breast. If fitting as a 1 or 2 sided corner fire, blanking panels will need to be fitted.
200mm / 7 7/8 Minimum regulations, and if not sure, always consult a professional. When purchased as part of a E-FX Media Wall, refer to those instructions. If purchased Using a tape measure and level, mark Drill the holes with a 10mm drill bit and fit the with a Suite &...
Page 9
FLAT WALL INSTALLATION FLAT WALL INSTALLATION TOP RAIL FIXING TABLE FIXING 1000 - 40” 1300 - 52” 1500 - 59” 1800 - 70” Next, using help if required, lift the fire onto the bottom bracket and push firmly against both 60mm Wall Screws brackets.
FLAT WALL INSTALLATION HARDWIRE INSTALLATION Finally, if using the power lead, on the underside of the fire, there is a clip to secure the cable in WARNING! place for safety. Before any wiring work is undertaken, make sure the power Unscrew this clip and place it around the cord before plugging the fire in securely.
Page 11
If you have a E-FX Lite fire, you will remove the log set, and the lighting panel found under Trim the power supply cables leaving 13mm the logs.
Page 12
HARDWIRE INSTALLATION HARDWIRE INSTALLATION Now trim the fire power cables by removing the terminals and leave 13mm of cable exposed to Now the mains cables are connected, connect the fire by inserted the trimmed cables into the connect the mains supply. The Neutral gray cable is a twin cable. corresponding connector.
This will ensure that nothing can be disconnected if the cable As standard one of the two rear screens in the E-FX fire has a reflective coating to mirror is accidentally pulled, so make sure its on securely.
Next, push the side glass back to the rear of the case. This will give SCREEN OPTION you room to fit the front glass in the next steps. For E-FX Lite Fires, you can make the If you have a Standard E-FX screen non reflective by removing the...
Page 15
FRONT GLASS INSTALLATION FRONT GLASS INSTALLATION You will notice a long gap on the underside of the opening in front of the heater grills. Make sure You will notice a long gap on the underside of the opening in front of the heater grills. Make sure Fit the glass handle by using an allen key to adjust the screw, and then slide the handle onto the the magnets on the glass are facing you.
In Standby Mode elSB 0.0005 0.0005 0.0005 0.0005 E-FX LITE E-FX LITE: INFORMATIONAL REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS MODEL 1000 - 40” 1300 - 51” 1500 - 59” 1800 - 70” Item @ 110V 60Hz Symbol Value...
TROUBLE SHOOTING TROUBLE SHOOTING PROBLEM CAUSE SOLUTION PROBLEM CAUSE SOLUTION Check lead in plugged in securely and p-clipped in place Turn fire off & on using the rocker switch next to keypad Mains lead not plugged in Lost rf connection to fire and repair the remote.
WIRING DIAGRAM PARTS LIST E-FX E-FX LITE PART 1000 1300 1500 1800 1000 1300 1500 1800 PART NAME NUMBER (40”) (52”) (59”) (70”) (40”) (52”) (59”) (70”) Top Hanging Bracket Bottom Hanging Bracket Power Lead E90-2 E90-2 E90-2 E90-2 E90-2...
NOTES NOTES E L E C T R I C F I R E S M A D E I N E U R O P E E L E C T R I C F I R E S M A D E I N E U R O P E...
Page 21
These products are only suitable for well insulated spaces or occasional use. Manufactured in the United Kingdom. All products are protected by patents, registered design and intellectual property rights. Flamerite Fires Ltd. will protect these rights. All specifications are correct at the time of publishing but are subject to change.
Need help?
Do you have a question about the E-FX and is the answer not in the manual?
Questions and answers