  • Page 1 INSTALLATION, PRECAUTIONS & SERVICING E-FX SL JULY 2024...
  • Page 2: Table Of Contents

    IMPORTANT INFORMATION CONTENTS • • Please bear in mind the weight of the The accessories are found in a box Important Information ..............................4 fire before removing from the packaging that is packed at the side of the fire. UKCA & CE Declarations ............................7 and installation.
  • Page 3 IMPORTANT INSTRUCTIONS IMPORTANT INSTRUCTIONS • • Cleaning and user maintenance shall NOT Extreme caution is necessary when any be made by children without supervision. heater is used by or near children or invalids and whenever the heater is left • Children of less than 3 years should be operating and unattended.
  • Page 4: Ukca & Ce Declarations

    IMPORTANT INSTRUCTIONS UKCA & CE DECLARATIONS TRADE NAME RATINGS PRODUCT TYPE MANUFACTURED BY Flamerite Fires LTD. Greenhough Road, Electric Fire (fan heater) E-FX 220-240 Vac, 50Hz Class I Lichfield. Staffs. WS13 7AU. (5120 BTU) United Kingdom. CAUTION REQUIREMENTS: BS-EN 60335-2-30:2009 + A11:2012...
  • Page 5: Etl Declarations

    ETL DECLARATIONS TECHNICAL SPECIFICATIONS TRADE NAME RATINGS PRODUCT TYPE MANUFACTURED BY Flamerite Fires LTD. Greenhough Road, Electric Fire (fan heater) E-FX 120 Vac, 60Hz Class I Lichfield. Staffs. WS13 7AU. (5120 BTU) United Kingdom. REQUIREMENTS: UL 2021 & CAN/CSA E60335-2-30...
  • Page 6: Required Tools

    REQUIRED TOOLS WHAT’S IN THE BOX... HAMMER & HEX KEY SCREWDRIVER E-FX FIRE LOG SET FRONT GLASS DRILL & TAPE MEASURE ACCESSORY & HARD- INSTRUCTIONS POWER LEAD DRILL BITS WIRE PACK REMOTE & GLASS HANDLE FIXING PACK BATTERIES PENCIL SPIRIT LEVEL E L E C T R I C F I R E S M A D E I N E U R O P E E L E C T R I C F I R E S M A D E I N E U R O P E...
  • Page 7: Before You Start

    BEFORE YOU START... FLAT WALL INSTALLATION PLUG SOCKETS & WALL CONSTRUCTION All fires must have an accessible plug. Do not fit a fire above a socket. Building regulations require Start by building the framework for the wall. The sizes are listed in a the table below for your fire. the socket to be located at the side of the unit.
  • Page 8 FLAT WALL INSTALLATION FLAT WALL INSTALLATION Now the framework and sockets are installed you can fix your fire to the frame. Be sure you plug Now the fire is installed you can attach the panels the wall. Make sure everything is working anything in before you start to add any panel work.
  • Page 9: Rear Screen Options

    FLAT WALL INSTALLATION REAR SCREEN OPTIONS E-FX FIRES Screw the panelling to the framework and make sure everything lines up and is working. We reccomend using 15-18mm or 9/16” - 11/16” finishing boards. This is so you can apply any As standard one of the two rear screens in the E-FX fire has a reflective coating to mirror finishes such as plaster coatings or decorative panelling.
  • Page 10: Hard-Wire Installation

    HARD-WIRE INSTALLATION REAR SCREEN OPTIONS Using the glass suction cup provided, WARNING! remove the rear glass. Leave the projection screen in place. You can Before any wiring work is undertaken make sure the then reconnect the fuelbed and screw power for the socket has been turned off at the fuse box it back into place.
  • Page 11 HARD-WIRE INSTALLATION HARD-WIRE INSTALLATION Fit the grounded outlet socket leaving enough power cable to get to the fire. Leave plenty of wire Disconnect the current power bracket found to trim back. on the right inside the fire. Remove the terminals from the power inlet and unscrew the bracket from the fire.
  • Page 12 HARD-WIRE INSTALLATION HARD-WIRE INSTALLATION Now trim the fire power cables by removing the terminals and leave 13mm (1/2”) of cable Now the main cables are connected connect the fire by inserting the trimmed cables into the exposed to connect the electric supply. The Neutral gray cable is a twin cable. corresponding connector.
  • Page 13: Front Glass Installation

    HARD-WIRE INSTALLATION FRONT GLASS INSTALLATION Before reinstalling the fuel bed, remove the cable clip from the hard-wire bracket and use it to To Install the front glass, first secure the electrical cable in place making sure that nothing can be disconnected if the cable is clean the glass with a soft accidentally pulled.
  • Page 14: Informational Requirements

    FRONT GLASS INSTALLATION INFORMATIONAL REQUIREMENTS E-FX SL Using the glass suction cup, pull the E-FX SL: INFORMATIONAL REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS glass forward slightly so you can fit the MODEL SL600 - 24” SL750 S- 30” SL750T - 30” SL1000 - 40”...
  • Page 15: Maintenance & Cleaning

    MAINTENANCE & CLEANING TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Main lead not plugged in Check lead in plugged in securely and p-clipped in place WARNING! NO POWER TO FIRE Circuit board Replacement part required Before any wiring work is undertaken, make sure the power for the socket has been turned off at the fuse box and check that Main socket Check socket is switched on...
  • Page 16: Wiring Diagram

    TROUBLE SHOOTING WIRING DIAGRAM PROBLEM CAUSE SOLUTION Turn fire off & on using the rocker switch next to keypad Lost rf connection to fire and re-pair the remote. See App instructions. REMOTE CONTROL NON RESPONSIVE Batteries Replace with 2 x AAA Debris from fuel bed Remove debris in channel...
  • Page 17: Parts List

    PARTS LIST EXPLODED DIAGRAM E-FX PART SL750T SL1000 PART NAME SL600 (24”) SL750S (30”) NUMBER (30”) (40”) Power Lead E90-2 E90-2 E90-2 E90-2 Motor Spindle M134 M135 M135 M136 280mm LED Patent Glass Projection Screen FE225 FE226 FE227 FE228 Rear Glass 150mm LED PCB Board LED Driver...
  • Page 18: Warranty

    NOTES WARRANTY 3 YEAR WARRANTY European Home warrants all Flamerite electric fireplaces against defects in materials and workmanship for a period of THREE (3) YEARS from the date of original retail purchase. If a defect exists, European Home will, at its option, either (1) repair the product at no charge, using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product.
  • Page 19 These products are only suitable for well insulated spaces or occasional use. Manufactured in the United Kingdom. All products are protected by patents, registered design and intellectual property rights. Flamerite Fires Ltd. will protect these rights. All specifications are correct at the time of publishing but are subject to change.

This manual is also suitable for: