DESIGN AND OPERATING PRINCIPLE
The ventilator consists of an indoor unit with a decorative front panel, a fan unit, a heat exchanger unit, located inside the air duct and
the outer ventilation hood.
TwinFresh Atmo Wi-Fi mini
In the
single cartridge.
Two filters are located inside the air duct in the airflow path to provide coarse air purification and prevent dust and foreign objects from
entering the heat exchanger and the fan.
In the bottom right corner of the front panel of the ventilator, there is a window for the IR remote control receiver combined with a light
sensor. The light sensor controls the brightness of the control panel LEDs.
The LEDs glow brighter during daylight hours and dimmer in the dark.
Prevents ingress of water and foreign objects into the ventilator.
Each ventilator model has a matching ventilation hood model.
Construction consisting of a fan and a regenerator.
Generates air flow, provides heat recovery.
TwinFresh Atmo mini
TwinFresh Atmo
6
TwinFresh Atmo Wi-Fi mini M
and
VENTILATOR DESIGN
Outer ventilation hood
Cartridge
Back part of the indoor unit
The assembly unit includes a circuit board and basic control units
located on the side of the indoor unit.
The design enables to shut off the air duct in case of an extended
downtime of the ventilator.
Front part of the indoor unit with a face panel
Fulfils the decorative function.
models, the fan and heat exchanger units are combined in a
Sound-absorbing material
A layer of sound-absorbing material for attenuation of
noise generated during the ventilator operation.
Air duct
Plastic air duct.
Atmo Wi-Fi (mini) (M)
Regenerator unit
Provides heat recovery.
Ventilation unit
Generates air flow.