3.6 Internal Terminals in Wiring Box

E
F
A
H
B
Item
Description
A
AC terminals
B
Grounding bar
C
PV terminals
D
MLPE terminal
E
COMM in terminal
F
COMM out terminal
G
AUX terminal
H
Battery terminals
NOTE!
Not all communication wirings connected with the terminals on the
communication board are shown in the picture.
Refer to the Section 6 for the details on communication connection.
16
G
C
D
B
3.7 Identification of EVERVOLT Hybrid Inverter
Parameter
Model
EVERVOLT HYBRID INVERTER
Model: EVHB-I7
PV INPUT
Max. DC Voltage
550 Vd.c.
Operating Voltage range
90-500 Vd.c.
No. of MPPT/String per MPPT
3/1
Max. DC Current per MPPT
16 A
Max. DC Power
11400 W
GRID OUTPUT/ INPUT
Nominal AC Voltage
120/240 Vac split phase
Max. Continuous Current
31.7 A
Max. Continuous AC Power
7608 VA
Nominal AC Frequency
60 Hz
Operating Frequency Range
59.3 Hz-60.5 Hz
AC Output Power Factor
0.8 Leading- 0.8 Lagging
BATTERY
Battery Type
Li-ion
1. Every EVERVOLT Hybrid Inverter product corresponds to a unique serial
number. The serial number is divided into five parts: type (3 bits)+ power (3 bits)+
year/month (2 bits)+ work order number (3 bits)+ stream number (3 bits), a total of
14bits.
2. The standard series number rules is as follows:
AH2
076
E
7
A1-6.0-US
Month Work Order Number
Model
Power
Year
EVERVOLT Hybrid Inverter
076: Power ----7.6 KW;
E: Year ------ I:2022 (A:2014; B: 2015......)
7: Month ------ July (October :A, November ;B, December......)
001: Work order number---- 001:001~999 (Monthly zero clearing)
001: Serial number---- 001:001~ZZZ (will be cleared for next work order).
Introduction
Serial NumberIdentification
Max. DC Current per MPPT
16 A
Max. DC Power
11400 W
GRID OUTPUT/ INPUT
Nominal AC Voltage
120/240 Vac split phase
Max. Continuous Current
31.7 A
Max. Continuous AC Power
7608 VA
Nominal AC Frequency
60 Hz
Operating Frequency Range
59.3 Hz-60.5 Hz
AC Output Power Factor
0.8 Leading- 0.8 Lagging
BATTERY
Battery Type
Li-ion
Nominal DC Voltage
150 Vd.c.
DC Operating Voltage Range
75-450 Vd.c.
Max. Charge / Discharge Current
54 A / 54 A
OTHER
Enclosure Type
Type 4X
-13˚F~+140˚F
Operating Temperature
no derating below 113˚F