Download Print this page

Troubleshooting Guide - Dakota Digital Odyssey ODYR-19-7 Operation

Dual, triple, or quad air pressure gauge

Advertisement

Troubleshooting guide.

Additional troubleshooting tips on the BIM-19-2 can be found in its separate manual.
Problem
Gauge will not light up
Gauge lights up, but displays
"NO SENDERS FOUND"
Gauge lights up, but displays
"BIM-19 SIGNAL ERROR"
Gauge lights up, but
displays "EE".
Gauge lights up, but
displays "--".
Gauge lights up, but does
not read correctly.
Gauge flashes constantly.
External warning indicator
does not work.
Gauge will not dim.
Gauge remains dim at all
times.
Possible cause
Red wire does not have
power.
BLACK wire is not getting
a good ground.
Gauge is damaged.
BIM-19 is not connected.
BIM-19 is not powered.
Data cable is not plugged in
securely.
BIM-19 is not connected.
BIM-19 is not powered.
Data cable is not plugged in
securely.
A BIM module other than a
BIM-19 is connected.
Sender is not connected
to BIM-19.
Wires are crossed or shorted.
Wire between BIM-19 and
sender is broken.
BIM-19 is damaged.
Sender is damaged.
Sender wire is shorted to
ground.
Wire between BIM-19 and
sender is broken.
BIM-19 is damaged.
Sender is damaged.
Loose connection on
power wire.
Poor sender ground.
Poor ground connection.
Incorrect sender type.
Warning limits are not set
properly.
Vehicle has improper air
pressure.
Indicator not connected
properly.
Indicator does not work.
Gauge output has been
damaged.
BLUE wire is not connected
correctly.
Gauge is damaged.
BLUE wire is getting power
all of the time.
Battery is very low.
Gauge is damaged.
Solution
Connect to a location that has power.
Connect ground to a different location.
Return gauge for repair. (see instructions)
Connect a BIM-19 using the power/data cable.
Check power connections on BIM-19.
Check both ends of the data cable.
Connect a BIM-19 using the power/data cable.
Check power connections on BIM-19.
Check both ends of the data cable.
The ODYR-19-7 is only compatible with the
BIM-19.
Connect wires from sender to BIM-19
terminals.
Verify sender connection to BIM-19.
Test and replace wire.
Return gauge for repair. (see instructions)
Return for replacement. (see instructions)
Check wire for damaged insulation, replace
if necessary.
Test and replace wire.
Return gauge for repair. (see instructions)
Return for replacement. (see instructions)
Reconnect wire going to PWR terminal.
Make sure gauge and BIM are getting a solid
ground.
Move ground to different location
Make sure sender has been replaced with
the correct type (SEN-03-9).
Reset warning limits.
Check air level and air pump.
Check indicator wiring connections.
Repair or replace indicator.
Return gauge for repair. (see instructions)
Check wiring connections.
Return gauge for repair. (see instructions)
Connect BLUE wire to location that only
has power when the headlights are on.
Recharge or replace vehicle battery.
Return gauge for repair. (see instructions)
MAN# 650447:A

Advertisement

loading

This manual is also suitable for: