Dual, triple, or quad air pressure gauge

Advertisement

Quick Links

DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE
Features:
All bag pressure readings displayed at once on a 2-line display.
Optional storage tank pressure readout.
A warning feature that flashes the gauge readout when outside operating limits.
An output for an external warning light or buzzer.
User adjustable warning points.
Individual settings for front, rear, and tank warning points.
Microprocessor stabilized readings.
Quick-Start feature to provide accurate readings quickly after being powered up.
Automatic Night dimming.
High Visibility, full character VFD display.
Automatic display selection for two, three, or four bag operation.
The air pressure gauge will read wet or dry air pressure. The sender used for this gauge
is an oil pressure sending unit, so it is compatible with air, water, oil, and fuel. The air pressure
gauge will operate and read correctly between the pressure range of 0 - 145 psi using the SEN-
03-1 senders and 0-400 psi using the SEN-03-5 senders. The sender for tank pressure is
always the SEN-03-5 400 psi unit. The gauge has a user adjustable low and high warning level.
Operation:
The gauge needs only the PWR and GND terminals connected to light up. When the
DIM terminal has 12 volts, it will dim the display for night viewing. The R-R, L-R, R-F, L-F, and
TNK terminals are for the pressure senders. The senders must be Dakota Digital part SEN-
03-1 or SEN-03-5. Sending units from other manufacturers will cause incorrect readings. SEN-
03 has 1/8" NPT threads. If other thread sizes are needed, an adapter fitting should be used to
change the thread size. If a sender is giving an incorrect reading, the display will show "EE". If
the sender is shorted to ground, the display will show "--".
The display will flash and the warning output will be set whenever one of the displayed
pressures is out of the warning set limits.
Using external warning indicators:
The WRN terminal provides a ground trigger whenever any of the senders are outside
the set limits. Low current indicators (less than 1/4 A) can be activated directly by connecting
their power wire to 12 volts and connecting their ground wire to the WRN terminal.
For higher current buzzers or lights, a relay will need to be used to switch the indicator
on. Dakota Digital's RLY-1 30A relay may be used for this. One of the coil wires should be
connected to 12 volts and the other coil wire connected to the WRN terminal. When the gauge
is outside its limits, the relay will turn on. The relay contact wires can be used to switch the
higher current.
WARNING! - CONNECTING A HIGH CURRENT INDICATOR DIRECTLY
ODYR-19-5 & SLX-19-5
TO THE WARNING OUTPUT WILL DAMAGE THE UNIT.

Advertisement

loading

Summary of Contents for Dakota Digital Odyssey ODYR-19-5

  • Page 1 For higher current buzzers or lights, a relay will need to be used to switch the indicator on. Dakota Digital’s RLY-1 30A relay may be used for this. One of the coil wires should be connected to 12 volts and the other coil wire connected to the WRN terminal. When the gauge is outside its limits, the relay will turn on.
  • Page 2 Setting the warning limit and sender type: The low and high warning limits can be set to different values, also the front bag, rear bag, and tank warnings can each be set differently. The push button switch on the front of the display is used for setting the warning limit.
  • Page 3 Wiring: PWR - connect to 12 volt accessory power. GND - connect to a good ground point in the vehicle. TNK - connect to tank pressure sender (optional). connect to the tail light circuit. WRN - can connect to the negative side of a relay, light, or buzzer. The TNK terminal should be left open if the tank pressure is not being monitored.
  • Page 4: Troubleshooting Guide

    Troubleshooting guide. Problem Possible cause Solution Gauge will not light up PWR terminal does not have Connect to a location that has power. power. GND terminal is not getting Connect ground to a different location. a good ground. Display harness is unplugged. Seat connectors in tightly at both ends. Gauge is damaged.
  • Page 5: Service And Repair

    ODYSSEY SERIES DIGITAL GAUGE LIMITED WARRANTY DAKOTA DIGITAL (the Company) warrants to the ORIGINAL PURCHASER of this product that should it, under normal use and condition, be proven defective in material or workmanship within 24 MONTHS FROM THE DATE OF PURCHASE, such defect(s) will be repaired or replaced (at the Company’s option) without charge for parts or labor directly related to repairs of the defect(s).

This manual is also suitable for: