APPLICATIONS
5-1 Application (1)
-
without Start/restart interlock function
without Relay monitoring function
-
Emitter
KM1
KM2
S1
E1
M
M: 3-phase motor
E1: 24 VDC Power supply
S1: External test switch
KM1, KM2: Electromagnet contactor (with Reinforced insulation)
Note: KM1 and KM2 must have reinforced insula-
tion between the coil and contacts.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Receiver
RS-485(A)
RS-485(B)
KM1 KM2
5-2 Application (2)
-
with Start/restart interlock function
with Relay monitoring function
-
Emitter
KM1
KM2
S1
S2
E1
M
M: 3-phase motor
E1: 24 VDC Power supply
S1: External test switch
S2: Restart interlock reset switch
KM1, KM2: Electromagnet contactor (with Reinforced insulation)
Note: KM1 and KM2 must have reinforced insula-
tion between the coil and contacts as well as
between contacts.
F3S-B
Section 5
Receiver
RS-485(A)
RS-485(B)
KM1 KM2
33