Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of their housing. The
burner consists of two separate parts (see pictures).
2. Unscrew the nozzles using a 7 mm socket spanner. Replace the nozzles
with models that are configured for use with the new type of gas (see Table
1). The two nozzles have the same hole diameter.
3. Replace all the components by completing the above operations in reverse
order.
• Adjusting the burners' primary air
Does not require adjusting.
• Setting the burners to minimum
1. Turn the tap to the low flame position;
2. Remove the knob and adjust the adjustment
screw, which is positioned in or next to the tap
pin, until the flame is small but steady.
3. Having adjusted the flame to the required low setting, while the burner is
alight, quickly change the position of the knob from minimum to maximum
and vice versa several times, checking that the flame does not go out.
4. Some appliances have a safety device (thermocouple) fitted. If the device
fails to work when the burners are set to the low flame setting, increase
this low flame setting using the adjusting screw.
5. Once the adjustment has been made, replace the seals on the by-passes
using sealing wax or a similar substance.
6. In the event of discrete-adjustment knobs with LED visualisation, turn the
knob to the minimum power setting them remove it and intervene on the
adjustment screw located near the tap pin.
! If the appliance is connected to liquid gas, the regulation screw must be
fastened as tightly as possible.
! Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. Stickers are available from any of our
Service Centres.
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be fitted to the
inlet pipe (in order to comply with current national regulations).
DATA PLATE
Electrical
see data plate
connections
ECODESIGN
This appliance conforms to the EU Regulation no. 66/2014
implementing Directive 2009/125/EC.
standard EN 30-2-1
GB
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pkl 751 t/ix/haPkll 751 t/ix/ha

Table of Contents