Summary
This product is an advanced digitally controlled infrared pyroelectric intelligent sensor
product.It uses the MCU to accurately calculate the switch information, and accurately
controls the relay to be turned on at the zero point of the sine wave, so that each load
is turned on. At the zero point of the sine wave, the inrush current problem caused by
the conventional control mode when the sine wave high voltage is turned on is
avoided, especially the large current damage relay generated by the large-capacity
capacitor under the impact of the high voltage under the load.
Due to the diversification of current electrical loads, especially LED lamps, energy-saving lamps, and fluorescent lamps
all have capacitors with different capacitances. This is a disaster for relays. Sometimes a 50W LED lamp can generate
surge currents of 80 to 120A. The 10A ordinary relay can only withstand 3 times of the inrush current, and it is likely that
the relay will be broken in a few days or several times. This is why the conventional sensor on the market has a short
life and a small load current.
In order to overcome this problem, this product adopts advanced digital precision calculation to turn on the load when
the sine wave is at zero potential, thus solving the load surge current problem, greatly enhancing the load capacity and
prolonging the service life of the product. The latest control method of mass production sensor technology can easily
control any load. It is a medium and high-end product. Although the cost is increased compared with the conventional
version, the reliability and life of the product are greatly increased. This product is equal to choosing peace of mind, and
choosing safety.
This product has a switching power supply version and a capacitor step-down version. The switching power supply
version has a working voltage of up to 100V-277V and a standby power consumption of <0.5W. In principle, the
capacitive step-down version can only have a single voltage, and the standby power consumption is >0.7W. You should
consider it when choosing a product.
Specifications
Power source: 220-240VAC,50Hz/60Hz
100-130VAC,50Hz/60Hz
All loads:1200W(220-240VAC)
800W(100-130VAC)
Time setting: 10sec-12min(adjustable)
Light-control: <10LUX-2000LUX(adjustable)
Sensor´s LED:
1. After power-on for 30 seconds, it enters the normal induction state. During this time, the LED lights flash
once every second.
2. It light once when the unit receives sensing signal.
Function
LUX adjustment:
LUX refers to the illuminance of the environment. Adjusting the LUX adjustment knob allows you to choose which
illuminance you want to get the sensor into the induction. Choose the habit that suits you.
Some of the choices in the 20LUX solution are to be illuminated. Some choose 50LUX ambient illumination to be
inductive lighting, and some choose to be inductive lighting at any time, as long as the LUX adjustment knob is
adjusted to the maximum.
105mm
59mm
Detection range(22°C): 3-12m (radii.)(adjustable)
Detection angle: 360º (ceiling installation)
Installation height: 2.5-4.5m
Working temperature: -10°C-+40°C
Working humidity: <93%RH
Sense motion speed: 0.6-1.5m/s
105mm
58mm
88.0mm

Advertisement

loading

Summary of Contents for pdlux PD-PIR101-Z

  • Page 1 PD-PIR101-Z Infrared Sensor Instruction 105mm 105mm 59mm 58mm Summary This product is an advanced digitally controlled infrared pyroelectric intelligent sensor product.It uses the MCU to accurately calculate the switch information, and accurately controls the relay to be turned on at the zero point of the sine wave, so that each load 88.0mm...
  • Page 2  Time adjustment: The time adjustment knob is used to adjust the time after the sensor senses the light, and the user can reasonably select the delay time after the induction. Sensor information 360° 3 X Detectors Height of installation2.5-4.5m Height of installation2.5-4.5m Detection angle Detection range(22℃)...
  • Page 3 -29B Installation instruction (1)Before installing switch off power; (2)Rotate top cover anti-clockwise and take off it, tighten off the screws fixing bottom cover; (3)Install the bottom cover on selected position with screw(like①); (4)According to the connection-wire diagram connect the power wire and load wire into the connection line column in sensor;...