Download Print this page

pdlux PD-MV1017B Instructions

Microwave sensor

Advertisement

Quick Links

PD-MV1017B Microwave Sensor Instruction
Summary
This is a hi-precision digital microwave sensor whose detection range is 360°and working frequency is
5.8GHz. It is based on Doppler principle which integrates the emitting and receiving. It adopts MCU (Micro
Control Unit) that greatly increases its precision and decreases its fault rate. It's delicate in appearance and
compact in structure. It can be independently connected to the loads or easily installed inside the lightings with
lampshade made of glass or plastic. It is widely applied in the passageway, washroom, elevator, household or
other public areas for security protection or energy saving. It applies for several technical patents and is the
perfect choice for your intelligent living.
EN 61058-1:2002+A2:2008
EN 50317:2002
EN 301 489-1 V1.8.1(2008-04)
EN 301 489-3 V1.4.1(2002-08)
EN 300 440-1 V1.5.1(2009-03)
EN 300 440-2 V1.3.1(2009-03)
Features
1.Non-radiation harm: its transmitter power is lower than 0.3mW, which does no harm to human body.
2.Reliable & Stable performance: it applies the RC filtering and digital filtering in digital processing. It also
uses the digital zero trigger technology, that is, at zero point it will be auto-connected or auto-disconnected. It
uses the Tyco high-power relay to control output, which ensures its reliable performance. It adopts power
management chip to guarantee its stable performance in 100-240V/AC.
3.Remote setting: it is designed with the remote function, that is, you can preset its function by potentiometer
or remote controller to your practical need.You can easily set and select the function within 12 meters.
Specifications
Power source: 100-240V/AC
Power frequency: 50/60Hz
Transmission power: <0.3mW
Rated load:
2400W/10A,Max,tungsten(cosφ=1)(220-240V/AC)
600W/5A,Max,fluorescent(cosφ=0.5)(220-240V/AC)
1200W/10A,Max,tungsten(cosφ=1)(100-130V/AC)
300W/5A,Max,fluorescent(cosφ=0.5)(100-130V/AC)
Working temperature: -15°C~+70°C
Protection level: IP20,Class II
53.5mm
17.7mm
50mm
Installation sit: indoors, ceiling mounting
HF system: 5.8GHz CW electric wave,ISM band
Detection angle: 360°(Ceiling installation),
180°(Wall installation)
Detection range:
1-11m (radii.) (adjustable),(Ceiling installation)
25m Max. (adjustable),(Wall installation)
Time setting: 8sec-12min, (adjustable)
Light-control: 10-1000LUX, (adjustable)
Power consumption: approx.0.5W
50mm
44mm
36mm
36mm
50mm

Advertisement

loading

Summary of Contents for pdlux PD-MV1017B

  • Page 1 PD-MV1017B Microwave Sensor Instruction 50mm 44mm 36mm 53.5mm 36mm 50mm 17.7mm 50mm Summary This is a hi-precision digital microwave sensor whose detection range is 360°and working frequency is 5.8GHz. It is based on Doppler principle which integrates the emitting and receiving. It adopts MCU (Micro Control Unit) that greatly increases its precision and decreases its fault rate.
  • Page 2: Sensor Information

    Sensor information Ceiling installation 360º Ground Detection range: 11m max (Height of installation4m) Detection range: 11m max (Height of installation2.5m) Sensing angle adjustment range Detection range: 10m max (Height of installation8m) Detection range: 10m max (Height of installation6m) Detection range: 10m max (Height of installation10m) Wall installation 25m Max.
  • Page 3: Time Setting

    Warning! Microwave will be reflected by the metal, thus the microwave sensor cannot be installed Nonmetals inside the shade made of metal, or it won’t When installed inside the ceiling or floor, the microwave sensor work normally. fails to distinguish the ambient light intensity automatically. The above application inside the lightings is one of multiple practical utilizations.
  • Page 4 NOTE:When the light be auto off,it will take 1 second before the sensor is ready to detect another movement,that is,only signal detected 1 seconds later can the light be auto-on. It is mainly for the adjustment of the delay time from the moment the signal detected and light auto-on till the light auto-off.
  • Page 5 Fault and the solution Fault Failure cause Solution Light-illumination is set incorrectly. Adjust the setting of the load. The load fails to work. The load is broken. Change the load. Turn the power on. The power is off. Check the settings of the The load works all the time.