5   OPERATION
machine to operate with electrode positive, insert and secure the polarity changeover cable into the
positive [+] terminal and the return lead into the negative [-] terminal. Be sure that the connections are
tight. Secure the work clamp to the work piece in a clean, debris-free location.
Secure the work clamp to the work piece in a clean, debris free location.
NOTE!
For some wires it is recommended to use negative polarity such as self-shielded flux-core.
See wire manufacturer's recommendation.
5.3

Drive system diagram

1. Wire inching/purge
2. Wire feed mechanism
5.4

Attaching fusion 180 GMAW gun

Direct plug GMAW guns install by inserting the power pin of the torch into the torch receptacle located
on the front of the unit and tightening the power pin retaining thumb screw. GMAW guns require a
control wire assembly to connect the trigger leads to the unit. The control wire assembly is located
near the power pin and plugs into the remote control socket.
WARNING!
The mains supply must be disconnected during installation.
1) Open wire feed compartment door and loosen retaining thumb screw.
2) Fit the MIG gun power pin into torch receptacle, insert fully.
3) Tighten retaining thumb screw.