CAUTION: To ensure adequate cooling, care should be taken to ensure that the
fan inlets and exhaust openings are free of obstructions.
1.5.

MOUNTING

The 7800FR Rack frame requires 3 rack units i.e. 5.25 inches (133 mm) of standard.19 inch (483 mm)
wide rack space. To securely fasten the frame to the equipment rack, make sure that all four mounting
screws are tightened securely.
When locating the frame within the rack, make sure that there is ample room at the rear so that the cables
do not obstruct the fan exhausts.
equipment, you need to ensure that the equipment does not protrude from the rack at the front, thus
interfering with the 7800FR door opening. It is recommended that the 1RU space immediately below the
frame does not protrude in front of the 7700FR to guarantee no interference. This is particularly important
for the QT version.
1.6.

POWER

1.6.1. Connecting the Power - AC Powered Frames

In addition, if you are installing the frame directly above other

Figure 1-1: AC Powered Frames Rear Panel

Revision 1.3
7800 MultiFrame Manual
7800FR 3 Rack Unit Frame
7800FR - 5